NED
UME-0034-03
XCM8060SA_8040SA_6040SA
27
4.1.4 Camera Control Commands
The table below shows the
list of Camera Control Commands
.
Table 4-1-4-1 List of Camera Control Commands
Control Item
CMD
VAL1
VAL2
VAL3
Control Description
Analog Gain
gax
0
to
20
x1.00...x11.22(1.06dB/step)
Digital Gain
gdx
0
to
511
x1...x2(x0.003906/step)
Digital Offset
odx
-15 to
15
-15...15(1DN/step
at8bit)-60...60(4DN/step at10bit)
Exposure Mode
inm
0 /1/2
Free Run / Ext Edge / Ext Level
Programmable
Exposure
Time
int
0 to 11
61 to
1023
32.5
~
117388.8
μs
(
XCM8060SA
)
48.8
~
1676083.2
μs
(
XCM8040SA
)
36.6
~
1257062.4
μs
(
XCM6040SA
)
(VAL1: Dividing, VAL2: Counter)
Output Signal Setting 1
voa
0 /1
0 to 9
8bit /10bit
、
Output block selection
Output Signal Setting 2
voc
0 /1
Linear /log
Setting Multi-Slope level
msl
0 to 15 0 to 15 0 to 15
Set the output level aspect of the vertex of
the multi-slope function
VAL1<=VAL2<=VAL3
Setting Multi-Slope timing
mst
0 to
511
0 to
511
0 to
511
Set the timing aspect of the vertex of the
multi-slope functionVAL1<=VAL2<=VAL3
i.e. when using 4 slopes, select values
such that VAL2/VAL1 and VAL3/VAL2
work out to the same result. Moreover, the
result should be less than 10.
Memory Initializing
rst
Reset to factory settings
Memory Load
rfd
Readout setup data in memory
Memory Save
sav
Store present setup data in memory
Test Pattern
tpn
0 /1
OFF/ON
Pixel Correction Data Save wht
Store pixel correction data in memory
Pixel Correction Setting
shc
0/1/2
0 to
1023
0:Correction
OFF
/1:Factory
white
correction
/2:User
white
correction,
Correction level (10-bit)