![NED XCM6040SAT2 User Manual Download Page 33](http://html1.mh-extra.com/html/ned/xcm6040sat2/xcm6040sat2_user-manual_3854190033.webp)
NED
UME-0027-03 XCM6040SAT2
33
<Example>
pad
□
10 CR
>OK
>pad 10
The increment of the line period depends on
the exposure time setting
command VAL1 in
“int”. For example, if VAL1 (in “int”)=1 and VAL1 (in
“pad”)=1, the increment is 12.5ns x 2 x 16 x 2=0.8
μs.
If VAL1 (in
“int”) = 3 and
VAL1 (in
“pad”)=1, the increment is 12.5ns x 2 x 16 x (2 x 2 x 2)=3.2
μs. And
if
VAL1 (in
“int”)=5 and VAL1 (in “pad”)=1, the increment is 12.5ns x 2 x 16 x (2 x
2 x 2 x 2 x 2)= 12.8
μs.
4.2.15 Returning the Cameras Settings to the its original status
Returns the current camera settings.
Format 1
CMD CR
CMD
sta
<Example>
sta CR
>OK
>Type=XCM6040SAT2
>Ver.=2.36_0x4425
>Serial=0
>check_code = 20070615
>gax 0
>gdx 0
>odx 0
>inm 0
>int 1,61
>cka 0
>voa 0,0
>voc 0
>tpn 0
>shc 1,900
>pad 0
>rev 0
>sta