NED
RMSL6K17GE
UM-0099-03
50
(Example)
(when “10” is set on “Encoder Divider”)
Encoder Divider: 10
4.2.7.6
Setting Encoder Output Mode
Sets the Encoder Output Mode to output the pulse.
・
Register name
Encoder Output Mode
・
VAL Off
(
Output no pulse
)
Position Up
(
Pulse output when new position in normal rotation
direction is detected
)
Position Down
(
Pulse output the pulse when new position in
reverse rotation direction is detected
)
Direction Up
(
Pulse output in normal rotation direction
)
Direction Down
(
Pulse output in reverse rotation direction
)
Motion
(
Pulse output in normal and reverse rotation directions
)
(Example)
(
when “Position Up ” is set on “Encoder Output Mode”)
Encoder Output Mode
: Position Up
4.2.7.7
Setting Encoder Status
Reads the Encoder status.
・
Register name
Encoder Status
・
VAL
Encoder Up
(
Encoder counter increasing
)
Encoder Down
(
Encoder counter decreasing
)
Encoder Idle (Encoder counter stopping)
Static
(
No operation in time of Encoder Timeout
)
4.2.7.8
Setting Time of Encoder Timeout
Sets the time of Encoder Timeout.
The status becomes “Encoder Idle” if the Encoder
counter does not change during this time.
・
Register name
Encoder Timeout
・
VAL 0
~
60000000