background image

INSTALLATION, USE, MAINTENANCE

DOC. NO.

H 155U 01

EDITION 2  00 12

UK

English

Page

1

Colibrì

Espresso

Instant

Summary of Contents for Colibri

Page 1: ...INSTALLATION USE MAINTENANCE DOC NO H 155U 01 EDITION 2 00 12 UK English Page 1 Colibr Espresso Instant...

Page 2: ......

Page 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Page 4: ......

Page 5: ...AND ADJUSTING THE MACHINE SETTINGS PAGE 14 STANDARD SETTINGS PAGE 14 ADJUSTING THE COFFEE UNIT PISTON STROKE SETTING PAGE 14 WATER TEMPERATURE CONTROL PAGE 14 ADJUSTING THE GRADE OF GRINDING PAGE 15 A...

Page 6: ...different operators Before installing and using the machine it is first neces sary to carefully read and understand the instructions contained in this manual as they offer important hints on safe inst...

Page 7: ...achine on a cabinet The machine can be installed on a table or on any other suitable stand recommended height is 820 mm If possible it is advisable to use the special cabinet which can house the liqui...

Page 8: ...e installed in the support cabinet optional AVAILABLE ADJUSTMENTS Grade of grinding for espresso coffee coffee and water doses by volume time adjustment for instant products Temperature control Factor...

Page 9: ...power consumption depends on many fac tors such as the temperature and ventilation of the room where it is installed the inlet water and boiler temperature etc The above power consumption calculated f...

Page 10: ...idator 8 Prearrangement for cashless payment systems MAINTENANCE AND DISINFECTION According to current safety rules and health regulations the operator of an automatic vending machine is respon sible...

Page 11: ...aper strip ensuring that the stirrers are all placed horizontally Replace the stirrer weight The stirrers must be burr free and not curved LOADING CUPS To load cups do as follows open the door slightl...

Page 12: ...ared chlorine based detergent reinstall the feeders and the water funnels reinstall the powder deposit drawers and the powder funnels after thoroughly drying them After reinstalling all parts the foll...

Page 13: ...mptying and cleaning The coffee container capacity is greater than that of the waste container if the support cabinet is not used Themachinecontrolsoftwareindicatesonthedisplay that themaximumnumberof...

Page 14: ...illed or at least once a week any powderresidueshouldberemovedfromtheexternalparts of the coffee unit particularly from the coffee funnel area see Fig 17 SUSPENDING FROM USE If for any reason the mach...

Page 15: ...Fig 9 CONNECTING THE MACHINE TO THE WATER MAINS The machine must be connected to the drinking water mains taking into account law provisions in force in the country where the machine is installed The...

Page 16: ...de the machine the only energised parts are the ones which are covered with protective cas ings which are marked with a plate indicating before removing the cover disconnect the electricity Before rem...

Page 17: ...xample during maintenance it is pos sible that an installation cycle is automatically started when the machine is switched on Versions with internal tank For models with an internal tank when the mach...

Page 18: ...spring 6 Swinging lever STANDARD SETTINGS The vending machine is supplied with the following set tings coffee temperature at the spout approx 70 80 C instant product temperature at the spout approx 70...

Page 19: ...re Installation Installation under way Sel not avail Selection disabled Coffee sel out For espresso models only Coffee unit out of service Take the drink Drink ready Fig 15 1 Coffee grinder 2 Grinding...

Page 20: ...he menu with the and buttons to highlight the following functions Compl selec Dispensing test including cup sugar and stirrer Powd only Dispensing powder only Water only Dispensing water only No Acces...

Page 21: ...ially if involving the use of a vehicle the hydraulic system must be emptied manually DISPLAYING THE STATISTICS Pressing button when the display indicates the Dis play statistics function causes the s...

Page 22: ...he accessories to be dispensed with each single button Discount determining the price reduction for selections without cup Special sales setting free vend and jug facilities parameters Euro displaying...

Page 23: ...cts power from the release motor and the machine locks LIQUID WASTE CONTAINER FULL If the machine is equipped with a liquid waste container housed in the cabinet fitted with an overflow warning device...

Page 24: ...6 validator coin lines can be changed The value of the lines is expressed in number of basic coins Press the confirm button from the programming menu to access the list of lines which can be scrolled...

Page 25: ...age is enabled or not ON OFF If the message is enabled when pressing the confirm button the first character will blink which can then be changed The buttons will be assigned the following functions 1...

Page 26: ...will be reset PROGRAMMER OPTIONAL AUTOMATIC SETUP TRANSFER Usingtheprogrammerdevicemakesitpossibletoreadout the programming routines set and transferred to other apparatuses from a given vending mach...

Page 27: ...unt Special sales Password for Free Vend Password for Jug facilities Number of selections for Jug facilities SETTING THE LANGUAGE It is possible to change the programmer configuration as concerns the...

Page 28: ...elevant systems must be checked by qualified per sonnel at least once a year Switch the machine off before any maintenance op erations which require removal of components The following operations must...

Page 29: ...rding to the use of the machine and the quality of the inlet water the entire foodstuff circuit system must be cleaned and sanitised in the following way all parts of the hydraulic system in contact w...

Page 30: ...DC the green LED when blinking indicates that the micro processor is working correctly the red LED indicates the operating status of the boiler heating element Fig 19 1 230 V users 2 RAM 3 EPROM 4 Inp...

Page 31: ...ties 5 To display board 6 Display contrast adjusting trimmer 7 Programming button 8 Cleaning button 9 RS232 port 10 To the programmer 11 Display board PUSH BUTTON BOARD This board controls the alphame...

Page 32: ...by NECTA VENDING SOLUTIONS SpA 28 0012 Colibr HYDRAULIC SYSTEM 1 Water inlet solenoid valve 2 Air break 3 Volumetric counter 4 Vibration pump 5 Bypass 6 Boiler 7 Coffee unit Espresso Instant...

Page 33: ...s Statistic N 1 Sel N 1 P xxxx Sel N 1 G xxxx Sel N 1 T xxxx Sel N 8 P xxxx Sel N 8 G xxxx Sel N 8 T xxxx Statistic N 2 Pr sel 1 XXXX Pr sel 8 XXXX Statistic N 4 FAILURE COUNTER LIST OF FAILURES N 1 A...

Page 34: ...m with the printer connected print all statistics as displayed Delete data Confirm Working After a few seconds all data is reset with the exception of the general counter Counter Counter ON OFF CASHED...

Page 35: ...ction 7 Sec Water only Selection 7 Sec No accessories Selection 7 Sec Dispensing Menu Dispensing Dispensing Dispensing TEST DISPENSING Special functions Key 2 1 Previous function 2 Grind and release a...

Page 36: ...mechanism N 4 RAM data N 5 Water failure N 6 Cup failure N 7 Water leak N 8 Volumetric counter N 9 Coffee unit N 10 Coffee failure N 11 Coffee release N 12 Cup release N 13 Liquid waste full dC XXXX A...

Page 37: ...TION 0 to 3 Previous price PRICE VALUE AND BUTTON STATUS Next price Set Prices Set Prices Button Button 1 ON Button 8 ON Button 1 ON Price N Basic unit PD Basic unit XXXX Dec point X Dec point Payment...

Page 38: ...OR SETTING Payment system Validator Executive std Credit Basic unit PD Power supply 12 24 V Coin line value A to F Line A Credit Excess credit available Price holding ECS UKey Initialising Validat lin...

Page 39: ...ment system Machine type C Espresso I Instant Tank Type of doses for Italy France Spain Great Britain Machine code Working List of layouts available per model country See selection dose table Water su...

Page 40: ...A nnnn P nnnn A nnnn P nnn A nnnn After entering 4th digit confirm new value P Programmed number of selec tions A Number of selections made P nnn A nnnn X Cancel Confirm Reset counters of selections...

Page 41: ...Display messages in available languages Italian French English Spanish Set Prices Whipping time Whipping d s XXX Whipping Selection Config Prom message Message xxxxxxxxxxxx To access programming Pass...

Page 42: ...6 Confirm function confirm data item 7 Change data item 8 Reset failures SELECTION CONFIGURATION Password Selection Config Cup release ON Button 8 Button 1 Cup release Special sales ON Enable Disable...

Page 43: ...N Euro Nat Nat Euro Disabled Special sales Discount Free Vend ON OFF Password XXXX Password XXXX ON Se OFF Se ON Jug Facilities ON Password XXXX Password XXXX Se OFF Remaining sel X Remaining sel X X...

Page 44: ...V 24 V TX DELAYED FUSE X COURRENT VAR VARISTOR VENT FAN CODE DESCRIPTION BDV BDV COIN MECH CONNECTOR CM1 COFFEE UNIT MOTOR CAM CMSB CUP RELEASE MOTOR CAM CV VOLUMETRIC COUNTER E1 SOLENOID VALVE INSTAN...

Page 45: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 46: ...NECTA VENDING SOLUTIONS SpA...

Page 47: ...Colibr Espresso...

Page 48: ...NECTA VENDING SOLUTIONS SpA...

Page 49: ...Colibr Instant...

Page 50: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 51: ...t any responsibility for any inaccuracies contained in this publication which can be ascribed to printing and or transcription errors All instructions drawings tables and information contained in this...