External Control                                    NEC LCD Monitor 

Rev.2.5 (G2) 

INDEX 

I. Application ....................................................................................................................... 4 
II. Preparation ..................................................................................................................... 5 
2. Connectors and wiring .................................................................................................... 5 

2.1 RS-232C Remote control .................................................................................................................... 5

 

2.2 LAN control ......................................................................................................................................... 5

 

III. Communication specification......................................................................................... 7 
3. Communication Parameter .............................................................................................. 7 

3.1 RS-232C Remote control .................................................................................................................... 7

 

3.2 LAN control ......................................................................................................................................... 7

 

3.3 Communication timing ....................................................................................................................... 7

 

4. Communication Format ................................................................................................... 8 

4.1 Header block format (fixed length) ................................................................................................... 9

 

4.2 Message block format ...................................................................................................................... 11

 

4.3 Check code ....................................................................................................................................... 13

 

4.4 Delimiter ........................................................................................................................................... 14

 

5. Message type ................................................................................................................ 15 

5.1 Get current Parameter from a monitor. .......................................................................................... 15

 

5.2 "Get parameter" reply ...................................................................................................................... 16

 

5.3 Set parameter ................................................................................................................................... 18

 

5.4 "Set parameter" reply ...................................................................................................................... 19

 

5.5 Commands ........................................................................................................................................ 20

 

5.5.1 Save Current Settings. .................................................................................................................. 20

 

5.5.2 Get Timing Report and Timing reply. ........................................................................................... 21

 

5.5.3 NULL Message ............................................................................................................................... 22

 

IV. Control Commands ....................................................................................................... 23 
6. Typical procedure example ........................................................................................... 23 

6.1. How to change the “Backlight” setting. ........................................................................................ 23

 

6.2. How to read the measurement value of the built-in temperature sensors. ................................ 26

 

6.3. Operation Code (OP code) Table .................................................................................................... 29

 

7. Power control procedure ............................................................................................... 44 

7.1 Power status read ............................................................................................................................ 44

 

7.2 Power control ................................................................................................................................... 46

 

8. Asset Data read and write ............................................................................................. 48 

8.1 Asset Data Read Request and reply ............................................................................................... 48

 

Summary of Contents for X754HB

Page 1: ...limiter 14 5 Message type 15 5 1 Get current Parameter from a monitor 15 5 2 Get parameter reply 16 5 3 Set parameter 18 5 4 Set parameter reply 19 5 5 Commands 20 5 5 1 Save Current Settings 20 5 5 2 Get Timing Report and Timing reply 21 5 5 3 NULL Message 22 IV Control Commands 23 6 Typical procedure example 23 6 1 How to change the Backlight setting 23 6 2 How to read the measurement value of t...

Page 2: ... Chanel Write Reply 81 15 Daylight Saving read write 82 15 1 Daylight Saving Read 82 15 2 Daylight Saving Write 84 16 Firmware Version 86 16 1 Firmware Version Read 86 17 Auto ID 88 17 1 Auto ID Execute 88 17 2 Auto ID Complete 90 17 3 Auto ID Reset 92 18 Input Name 93 18 1 Input Name Read 93 18 2 Input Name Write 95 18 3 Input Name Reset 97 19 Auto Tile Matrix 99 19 1 Auto Tile Matrix Execute 99 ...

Page 3: ...py Read 119 21 2 Setting Copy Write 121 21 3 Setting Copy Start 123 22 Security Enable 125 22 1 Security Enable Read 125 22 2 Security Enable Write 127 23 LAN MAC Address 129 23 1 LAN MAC Address Read 129 24 Proof of Play 131 24 1 Set Proof of Play Operation Mode 131 24 2 Get Proof of Play Current 133 24 3 Get Proof of Play Status 135 24 4 Get Proof of Play Number to Number 137 ...

Page 4: ...is document defines the communications method for control of the NEC LCD monitor MultiSync P403 P463 P553 P703 P801 X464UN X554UN X464UNV X554UNS X474HB X464UNS X554UNV X555UNS X555UNV X754HB when using an external controller ...

Page 5: ...32C Remote control Connector 9 pin D Sub Cable Cross reversed cable or null modem cable Please refer Controlling the LCD monitor via RS 232C Remote control on User s manual 2 2 LAN control Connector RJ 45 10 100 BASE T Cable Category 5 or higher LAN cable ...

Page 6: ... 6 139 Please refer Controlling the LCD monitor via LAN control on User s manual ...

Page 7: ...ult Automatic setup If you need to change Please refer Network settings on User s manual 5 Port No 7142 Fixed Note The monitor will disconnect the connection if no packet data is received for 15 minutes And the controller PC has to re connect to control the monitor again after 15 minutes or more 3 3 Communication timing The controller should wait for a reply packet before the next command is sent ...

Page 8: ...ted item The controller sends commands to set an adjusted value The monitor replies to the controller for confirmation The controller sends command to get a value for confirmation The monitor replies an adjusted value The controller requests to store the adjusted value to the monitor Command Command Reply The control does not suitable for above fixed protocol use the proper command for each contro...

Page 9: ...80 90h 6 46h F 31 5Fh 56 78h 81 91h 7 47h G 32 60h 57 79h 82 92h 8 48h H 33 61h 58 7Ah 83 93h 9 49h I 34 62h 59 7Bh 84 94h 10 4Ah J 35 63h 60 7Ch 85 95h 11 4Bh K 36 64h 61 7Dh 86 96h 12 4Ch L 37 65h 62 7Eh 87 97h 13 4Dh M 38 66h 63 7Fh 88 98h 14 4Eh N 39 67h 64 80h 89 99h 15 4Fh O 40 68h 65 81h 90 9Ah 16 50h P 41 69h 66 82h 91 9Bh 17 51h Q 42 6Ah 67 83h 92 9Ch 18 52h R 43 6Bh 68 84h 93 9Dh 19 53h ...

Page 10: ...Case sensitive Refer to section 4 2 Message block format for more details ASCII A 41h Command ASCII B 42h Command reply ASCII C 43h Get current parameter from a monitor ASCII D 44h Get parameter reply ASCII E 45h Set parameter ASCII F 46h Set parameter reply 6th 7th bytes Message Length Specify the length of the message that follows the header from STX to ETX This length includes STX and ETX The b...

Page 11: ...er reply for more details 3 Set parameter The controller sends this message to change a setting of the monitor Message format of the Set parameter is as follows Ø Refer to section 5 3 Set parameter for more details 4 Set Parameter reply The monitor replies with this message for a confirmation of the Set parameter message Message format of the Set parameter reply is as follows Ø Refer to section 5 ...

Page 12: ... power control Schedule etc Refer to section 5 5 Commands message for more details 6 Command reply The monitor replies to a query from the controller Command reply message format depends on each command Refer to section 5 5 Commands message for more details ...

Page 13: ...30h xor 30h xor 31h xor 30h xor 30h xor 30h xor 36h xor 34h xor 03h 77h Header Message Check code Delimiter 27 26 25 24 23 22 21 20 SOH D0 Reserved D1 Destination D2 Source D3 Type D4 Length H D5 Length L D6 STX D7 Data D8 ETX Dn Check code Dn 1 P P P P P P P P Header Message Check code BCC Delimiter SOH Reserved Destination Address Source Address Message type Message length STX OP code page OP co...

Page 14: ... 14 139 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter ...

Page 15: ...em OP code page data must be encoded to ASCII characters Ex The byte data 02h must be encoded to ASCII characters 0 and 2 30h and 32h OP code page 02h OP code page Hi ASCII 0 30h OP code page Lo ASCII 2 32h Refer to Operation code table Appendix A 4th 5th bytes OP code Operation code Refer to Appendix A Operation code table for each item OP code data must be encoded to ASCII characters Ex The byte...

Page 16: ...ode Operation code These bytes indicate a replying item s OP code This returned value from the monitor is encoded to ASCII characters Refer to the operation code table Ex The byte data 1Ah is encoded to ASCII character 1 and A 31h and 41h 8th 9th bytes Type Operation type code 00h Set parameter 01h Momentary Like the Auto Setup function which automatically changes the parameter This returned value...

Page 17: ... 17 139 18th byte ETX End of Message ASCII ETX 03h ...

Page 18: ... 0 and 2 30h and 32h Refer to the Operation code table 4th 5th bytes OP code Operation code This OP code data must be encoded to ASCII characters Ex OP code 1Ah OP code Hi ASCII 1 31h OP code Lo ASCII A 41h Refer to the Operation code table 6th 9th bytes Set value 16bit This data must be encoded to ASCII characters Ex 0123h 1st MSB ASCII 0 30h 2nd ASCII 1 31h 3rd ASCII 2 32h 4th LSB ASCII 3 33h 10...

Page 19: ...or is encoded to ASCII characters Ex OP code 1Ah OP code Hi ASCII 1 31h OP code Lo ASCII A 41h Refer to Operation code table 8th 9th bytes Type Operation type code ASCII 0 0 30h 30h Set parameter ASCII 0 1 30h 31h Momentary Like Auto Setup function that automatically changes the parameter 10th 13th bytes Max value Maximum value that monitor can accept 16bits Reply data from the monitor is encoded ...

Page 20: ...quests for the monitor to store the adjusted value Ø Send OC 30h 43h as Save current settings command Ø Complete Save Current setting command packet as follows ASCII 01h 30h 41h 30h 41h 30h 34h 02h 30h 43h 03h CHK 0Dh SOH 0 A 0 A 0 4 STX 0 C ETX CHK CR The monitor replies the packet for confirmation as follows SOH 0 0 A B 0 6 STX 0 0 0 C ETX CHK CR STX Command code ETX 0 C ...

Page 21: ...lies status as the following format Ø SS Timing status byte Bit 7 1 Sync Frequency is out of range Bit 6 1 Unstable count Bit 5 2 Reserved Don t care Bit 1 1 Positive Horizontal sync polarity 0 Negative Horizontal sync polarity Bit 0 1 Positive Vertical sync polarity 0 Negative Vertical sync polarity Ø H Freq Horizontal Frequency in unit 0 01kHz Ø V Freq Vertical Frequency in unit 0 01Hz Ex When H...

Page 22: ...sage will be returned by the monitor if the Start Proof of Play command is sent and the monitor has already started Proof of Play Ø A null message will be returned by the monitor if the Stop Proof of Play command is sent and the monitor has not started Proof of Play Ø Complete NULL Message command packet as follows 01h 30h 30h 41h 42h 30h 34h 02h 42h 45h 03h CHK 0Dh SOH 0 0 A B 0 4 STX B E ETX CHK...

Page 23: ... 0 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 2 The monitor replies with current Backlight setting and capability to support this operation Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set ...

Page 24: ... confirmation Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 F 46h Message Type is Set parameter reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 0 30h 30h Result code No error 0 0 30h 30h Operation code page number is 0 1 0 31h...

Page 25: ... Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID which you want to store the setting Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller A 41h Message type is Command 0 4 30h 34h Message length is 4 bytes Message STX 02h Start of Message 0 C 30h 43h Command code is 0Ch as Save current settings ETX 03h End of Message Check code BCC Block Check Code Refer to the s...

Page 26: ... 2 0 0 0 1 30h 30h 30h 31h Select the temperature sensor 1 01h 00h No meaning 01h Sensor 1 02h Sensor 2 03h Sensor 3 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 2 The monitor replies for confirmation Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ...

Page 27: ...peration code is 79h in the page 2 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 4 The monitor replies a temperature of selected sensor Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A th...

Page 28: ...k code for a BCC calculation Delimiter CR 0Dh End of packet Temperature Celsius Readout value Binary Hexadecimal 125 0 0000 0000 1111 1010 00FAh 25 0 0000 0000 0011 0010 0032h 0 5 0000 0000 0000 0001 0001h 0 0000 0000 0000 0000 0000h 0 5 1111 1111 1111 1111 FFFFh 25 0 1111 1111 1100 1110 FFCEh 55 0 1111 1111 1001 0010 FF92h ...

Page 29: ...h 10000K 100K step COLOR TEMPERATURE CUSTOM 00h 14h 9 10000K 11 0Bh CUSTOM R GAIN 00h 16h 0 Dark 255 FFh Bright B GAIN 00h 18h 0 Dark 255 FFh Bright G GAIN 00h 1Ah 0 Dark 255 FFh Bright COLOR CONTROL 00h RED 9Bh YELLOW 9Ch GREEN 9Dh CYAN 9Eh BLUE 9Fh MAGENTA A0h 0 100 64h center 200 C8h GAMMA CORRECTION 02h 68h 0 No mean 1 NATIVE 4 2 2 8 2 4 7 S GAMMA 5 DICOM SIM 6 PROGRAMABLE1 13 0Bh PROGRAMABLE2...

Page 30: ...RESET PICTURE 02h CBh 0 No mean 2 Reset Picture category Momentary ADJUS T AUTO SETUP 00h 1Eh 0 No mean 1 Execute Momentary AUTO ADJUST 10h B7h 0 No mean 1 OFF 2 ON H POSITION 00h 20h 0 Left side Max Right side Depends on a display timing V POSITION 00h 30h 0 Bottom side Max Top side Depends on a display timing CLOCK 00h 0Eh 0 Max PHASE 00h 3Eh 0 Max H RESOLUTION 02h 50h 0 Low Max High V RESOLUTIO...

Page 31: ...366x768 ASPECT 02h 70h 0 No mean 1 NORMAL 2 FULL 3 WIDE 4 ZOOM 6 DYNAMIC 7 1 1 Wide Dynamic A V mode only Zoom Control ZOOM 11h 2Ch 0 89 59h No mean 90 5Ah 90 91 5Bh 91 100 64h 100 300 12Ch 300 The following commands can also be used OP code page 02h OP code 6Fh Parameter 0 No mean 1 100 2 101 201 C9h 300 H ZOOM 11h 2Dh 0 89 59h No mean 90 5Ah 90 91 5Bh 91 100 64h 100 300 12Ch 300 The following co...

Page 32: ... side IMAGE FLIP 02h D7h 0 No mean 1 NONE 2 H FLIP 3 V FLIP 4 180 ROTATE OSD FLIP 10h B8h 0 No mean 1 OFF 2 ON RESET ADJUST 02h CBh 0 No mean 3 Reset Adjust category Momentary AUDI O VOLUME 00h 62h 0 whisper 100 64h loud BALANCE 00h 93h O Left 30 1Eh Center 60 3Ch Right 00h 94h 0 No mean 1 MONAURAL 2 STEREO TREBLE 00h 8Fh O Min 6 Center 12 0Ch Max BASS 00h 91h 0 Min 6 Center 12 0Ch Max PIP AUDIO 1...

Page 33: ...5h 0 No mean 1 No 1 Enable 7 No 7 Enable DISABLE 02h E6h 0 No mean 1 No 1 Disable 7 No 7 Disable SCHEDULE SETTINGS Refer to chapter 10 DATE TIME Refer to chapter 9 DAYLIGHT SAVING Refer to chapter 9 and 15 RESET SCHEDULE 02h CBh 0 No mean 5 Reset Schedule category Momentary PIP KEEP PIP MODE 10h 82h 0 No mean 1 OFF 2 ON PIP MODE 02h 72h 0 No mean 1 OFF 2 PIP 3 POP 4 STILL 5 PICTURE BY PICTURE ASPE...

Page 34: ... DVI 4 HDMI Set only 5 VIDEO 7 S VIDEO 12 0Ch Y Pb Pr 13 0Dh OPTION 14 0Eh Y Pb Pr2 SCART 15 0Fh DPORT 16 10h DPORT2 17 11h HDMI 18 12h HDMI2 128 80h DPORT3 This operation has limitation of selection Please refer to the monitor instruction manual RESET PIP 02h CBh 0 No mean 6 Reset PIP Category Momentary OSD LANGUAGE 00h 68h 0 No mean 1 ENGLISH 2 GERMAN 3 FRENCH 4 SPANISH 5 JAPANESE 6 ITALIAN 7 SW...

Page 35: ... No mean 1 Display a Memo 2 Undisplay a Memo RESET OSD 02h CBh 0 No mean 7 Reset OSD category Momentary MULTI DIS PLAY MONITOR ID 02h 3Eh 1 100 ID GROUP ID 10h 7Fh 0 No assignment 1 Group A 2 Group B 3 Group AB 4 Group C 5 Group AC 1023 3FFh Group ABCDEFGHIJ Bit0 Group A Bit1 Group B Bit2 Group C Bit3 Group D Bit4 Group E Bit5 Group F Bit6 Group G Bit7 Group H Bit8 Group I Bit9 Group J AUTO ID Ref...

Page 36: ... mean 1 10 0Ah Number of V division POSITION 02h D2h 0 No mean 1 100 64h TILE COMP 02h D5h 0 No mean 1 NO 2 YES ENABLE 02h D3h 0 No mean 1 NO 2 YES FRAME COMP 11h 01h 0 No mean 1 NONE 2 AUTO 3 MANUAL Available on X464UN X554UN X464UNV X554UNS AUTO 11h 02h 0 No mean 50 32h 0 5F 100 64h 1 0F 150 96h 1 5F 200 C8h 2 0F Available on X464UN X554UN X464UNV X554UNS This command is used when FRAME COMP is ...

Page 37: ...h 0 No mean 1 ON 2 OFF POWER INDICATOR 02h BEh 0 No mean 1 ON 2 OFF SETTING COPY Refer to Chapter 21 RESET MULTI DISPLAY 02h CBh 0 No mean 8 Reset Multi Display Category Momentary DISPL AY P ROTE CTIO N POWER SAVE Refer to Chapter 20 HEAT STATUS FAN1 2 3 02h 7Ah 7Bh Select target FAN 7Ah 0 No mean 1 FAN 1 2 FAN 2 3 FAN 3 Read status of target FAN 7Bh 0 OFF 1 ON 2 ERROR Read Only BACKLIGHT Refer to...

Page 38: ...OM 10h 35h 0 95 5 100 10 0Ah 105 SIDE BORDER COLOR 02h DFh 0 Black 100 64h White CHANGE PASSWORD N A SECURITY Refer to Chapter 22 RESET DISPLAY PROTECTION 02h CBh 0 No mean 9 Reset Display Protection category Momentary EXTER NAL CONT ROL IP ADDRESS SETTING N A MAC ADDRESS Refer to Chapter 23 LAN POWER 10h D3h 0 No mean 1 OFF 2 ON DDC CI 10h BEh 0 No mean 1 OFF 2 ON PING N A IP ADDRESS RESET N A RE...

Page 39: ...ION 02h 5Ah 0 7 SYNC TERMINATION 02h E1h 0 No mean 1 HIGH 2 LOW INPUT CHANGE INPUT CHANGE 10h 86h 0 No mean 1 NORMAL 2 QUICK 3 SUPER When you set up SUPER please set up INPUT1 and INPUT2 first INPUT1 10h CEh 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 VIDEO 7 S VIDEO 12 0Ch Y Pb Pr 13 0Dh OPTION 14 0Eh Y Pb Pr2 15 0Fh DPORT 16 10h DPORT2 17 11h HDMI 18 12h HDMI2 128 80h DPORT3 INPUT2 10h CFh ...

Page 40: ...POWER 10h 41h 0 OFF 1 ON AUDIO 10h B0h 0 No mean 1 ANALOG 2 DIGITAL INTERNAL PC OFF WARNIN G 10h C0h 0 No mean 1 OFF 2 ON AUTO OFF 10h C1h 0 No mean 1 OFF 2 ON START UP PC 10h C2h 0 No mean 1 Execute FORCE QUIT 10h C3h 0 No mean 1 Execute 120Hz 10h 87h 0 No mean 1 ON 2 OFF TOUCH PANEL STANDBY 10h C4h 0 No mean 1 OFF 2 ON PC SOURCE 10h C5h 0 No mean 1 AUTO 2 EXTERNAL PC RESET ADVANCED OPTION1 02h C...

Page 41: ...ean 1 Off 2 On VOLUM E 10h C7h 0 whisper 100 64h loud INPUT SELECT ON OF F 10h DFh D0h 0 No mean 1 Off 2 On INPUT 10h D0h 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 VIDEO 7 S VIDEO 12 0Ch Y Pb Pr 13 0Dh OPTION 14 0Eh Y Pb Pr2 SCART 15 0Fh DPORT 16 10h DPORT2 17 11h HDMI 18 12h HDMI2 128 80h DPORT3 WAITING TIME 10h 78h 30 1Eh short 600 258h long 1step 1sec INTELLI WIRELESS DATA 10h ECh 0 No m...

Page 42: ... HDMI2 VOLUME UP DOWN 00h 62h 0 whisper 100 64h loud MUTE 00h 8Dh 0 UNMUTE Set only 1 MUTE 2 UNMUTE SCREEN MUTE 10h B6h 0 No mean 1 SCREEN MUTE ON 2 SCREEN MUTE OFF MTS 02h 2Ch 0 No mean 1 Main 2 Sub 3 Main Sub This operation requires supported option TV tuner SOUND 02h 34h 0 No mean 1 Off 2 ON Same as SURROUND PICTURE MODE 02h 1Ah 0 No mean 1 sRGB 3 HIGHBRIGHT 4 STANDARD 5 CINEMA 8 CUSTOM1 9 CUST...

Page 43: ...PTURE 02h 76h 0 OFF 1 CAPTURE Momentary SIGNAL INFORMATION 02h EAh 0 No mean 1 OFF 2 ON AUTO SETUP 00h 1Eh 0 No mean 1 Execute Momentary TV CHANNEL UP DOWN 00h 8Bh 0 No mean 1 UP 2 DOWN This operation requires supported option TV tuner TEMPE RATU RE S ENSO R SELECT TEMPERATURE SENSOR 02h 78h 0 No mean 1 SENSOR 1 2 SENSOR 2 3 SENSOR 3 READOUT A TEMPERATURE 02h 79h Returned value is 2 s complement R...

Page 44: ...iter CR 0Dh End of packet 2 The monitor returns with the current power status Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message Type is Command reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 2 30h 32h Reserved data ...

Page 45: ... 45 139 Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 46: ...ion Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be written to the monitor at a time is 32bytes Ex The byte data 20h is encoded as ASCII characters 2 and 0 32h and ...

Page 47: ... 47 139 Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 48: ... of the Asset data At first set 00h Read data from the top of Asset data area 2 0 32h 30h Read out data length is 32bytes Secondly set 20h Read data from the 32bytes offset point in the Asset data area Maximum readout length is 32bytes at a time ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The moni...

Page 49: ... 49 139 Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 50: ...nd of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX 0 0 C 0 0 E 0 0 Data 0 Data 1 Data N ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate...

Page 51: ... 51 139 CR 0Dh End of packet ...

Page 52: ...f Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Date Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 4 STX C 3 1 1 YY MM DD WW HH MN DS ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a reply...

Page 53: ...sday 0 5 30h 35h Friday 0 6 30h 36h Saturday HH Hours 0 0 30h 30h 0 1 7 31h 37h 23 17h MN Minutes 0 0 30h 30h 0 3 B 33h 42h 59 3Bh DS Daylight saving Summer time 0 0 30h 30h NO 0 1 30h 31h YES ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 54: ...gth Message STX 02h Start of Message C 2 1 2 43h 32h 31h 32h Date Time write command YY MM DD WW HH MN DS Date Time data YY Year offset 2000 0 0 30h 30h 2000 6 3 36h 33h 2099 99 63h MM Month 0 1 30h 31h JANUARY 0 C 30h 43h DECEMBER DD Day 0 1 30h 31h 1 1 E 31h 45h 30 1Eh 1 F 31h 46h 31 1Fh WW weekdays 0 0 30h 30h SUNDAY 0 1 30h 31h MONDAY 0 2 30h 32h TUESDAY 0 3 30h 33h WEDNESDAY 0 4 30h 34h THURS...

Page 55: ...rt of Message C 3 1 2 43h 33h 31h 32h Date Time write reply command ST Date Time Status command 0 0 30h 30h No error 0 1 30h 31h Error YY MM DD WW HH MN DS Date Time data YY Year offset 2000 0 0 30h 30h 2000 6 3 36h 33h 2099 99 63h MM Month 0 1 30h 31h JANUARY 0 C 30h 43h DECEMBER DD Day 0 1 30h 31h 1 1 E 31h 45h 30 1Eh 1 F 31h 46h 31 1Fh WW weekdays 0 0 30h 30h SUNDAY 0 1 30h 31h MONDAY 0 2 30h 3...

Page 56: ... 56 139 Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 57: ...ck Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Schedule to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 2 6 STX C 3 2 1 PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the...

Page 58: ...0h 44h OPTION 0 E 30h 45h Y Pb Pr2 SCART 0 F 30h 46h DPORT 1 0 31h 30h DPORT2 1 1 31h 31h HDMI 1 2 31h 32h HDMI2 8 0 38h 30h DPORT3 WD Week setting bit 0 MONDAY bit 1 TUESDAY bit 2 WEDNESDAY bit 3 THURSDAY bit 4 FRIDAY bit 5 SATURDAY bit 6 SUNDAY EX 0 1 30h 31h MONDAY 0 4 30h 34h TUESDAY 0 F 30h 46h MONDAY TUESDAY WEDNESDAY and THURSDAY 7 F 37h 46h MONDAY to SUNDAY FL Option bit 0 0 once 1 Everyda...

Page 59: ...0 EXT4 Extension 4 0 0 30h 30h On this monitor it is always 00 EXT5 Extension 5 0 0 30h 30h On this monitor it is always 00 EXT6 Extension 6 0 0 30h 30h On this monitor it is always 00 EXT7 Extension 7 0 0 30h 30h On this monitor it is always 00 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 60: ...f Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Schedule to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 6 STX C 3 1 3 PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Mo...

Page 61: ...IDEO 0 5 30h 35h S VIDEO 0 7 30h 30h No mean Works on last memory WD Week setting bit 0 MONDAY bit 1 TUESDAY bit 2 WEDNESDAY bit 3 THURSDAY bit 4 FRIDAY bit 5 SATURDAY bit 6 SUNDAY EX 0 1 30h 31h MONDAY 0 4 30h 34h TUESDAY 0 F 30h 46h MONDAY TUESDAY WEDNESDAY and THURSDAY 7 F 37h 46h MONDAY to SUNDAY FL Option bit 0 0 once 1 Everyday bit 1 0 once 1 Every week bit 2 0 Disable 1 Enable EX 0 1 30h 31...

Page 62: ... PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn on time minute 0 0 30h 30h 0 3 B 33h 42h 59 3 C 33h 43h On timer isn t set OFF_HOUR Turn off time hour 0 0 30h 30h 00 1 7 31h 3...

Page 63: ...EX 0 1 30h 31h Disable Everyday 0 4 30h 34h Enable once P MODE Picture mode 0 0 30h 30h No mean works on last memory 0 1 30h 31h sRGB 0 3 30h 33h HiGHBRIGHT 0 4 30h 34h STANDARD 0 5 30h 34h CINEMA 0 D 30h 44h CUSTOM1 0 E 30h 45h CUSTOM2 Please select active picture mode on your system setting If you select inactive picture mode here the input change execution will be ignored EXT1 Extension1 0 0 30...

Page 64: ...essage C 3 2 2 43h 33h 32h 32h Schedule writes reply command ST Schedule Status command 0 0 30h 30h No error 0 1 30h 31h Error PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn o...

Page 65: ...ay 0 4 30h 34h Enable once P MODE Picture mode 0 0 30h 30h No mean works on last memory 0 1 30h 31h sRGB 0 3 30h 33h HIGHBRIGHT 0 4 30h 34h STANDARD 0 5 30h 34h CINEMA 0 D 30h 44h CUSTOM1 0 E 30h 45h CUSTOM2 EXT1 Extension1 0 0 30h 30h On this monitor it is always 00 EXT2 Extension 2 0 0 30h 30h On this monitor it is always 00 EXT3 Extension 3 0 0 30h 30h On this monitor it is always 00 EXT4 Exten...

Page 66: ...ble 0 1 30h 31h Enable ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 4 The monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 C STX C 3 1 5 ST PG EN ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor...

Page 67: ... 67 139 0 1 30h 31h Enable ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 68: ... command PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn on time minute 0 0 30h 30h 0 3 B 33h 42h 59 3 C 33h 43h On timer isn t set OFF_HOUR Turn off time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h Off timer is...

Page 69: ... Check code Delimiter SOH 0 0 Monitor ID B 1 8 STX C 3 1 4 ST PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 1 8 31h 38h Message length Message STX 02h Start of Mess...

Page 70: ...0h 46h MONDAY TUESDAY WEDNESDAY and THURSDAY 7 F 37h 46h MONDAY to SUNDAY FL Option bit 0 0 once 1 Everyday bit 1 0 once 1 Every week bit 2 0 Disable 1 Enable When bit 0 and bit 1 are 1 it behaves as Everyday EX 0 1 30h 31h Disable Everyday 0 4 30h 34h Enable once ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End o...

Page 71: ...C STX C 3 1 5 ST PG EN ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 0 C 30h 43h Message length Message STX 02h Start of Message C 3 1 5 43h 33h 31h 35h Enable Disable Schedule writes reply command ST Enable Dis...

Page 72: ...eader SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be written to the monitor at a time is 32bytes Ex The byte data 20h is encoded as ASCII characters 2 and 0 34h and 30h M...

Page 73: ...o signal D 0 44h 30h D0 PROOF OF PLAY buffer reduction E 0 45h 30h E0 System error ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 74: ... N STX C 3 1 6 Data 0 Data 1 Data n ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be returned from the monitor at a time is 32bytes Ex The byte data 20h i...

Page 75: ... 75 139 Note No null termination character is sent ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 76: ...1h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be returned from the monitor at a time is 32bytes Ex The byte data 20h is encoded as ASCII characters 2 and 0 32h and 30h Message S...

Page 77: ... 77 139 Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 78: ... code Delimiter SOH 0 MonitorID 0 A 1 0 STX C 2 1 D EN P1 P2 P3 P4 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID of which you want to change a setting Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller A 41h Message type is Command 1 0 31h 30h Message length Message STX 02h Start of Message C 2 1 D 43h 32h 31h 44h Security Lock Contr...

Page 79: ...or ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length Message STX 02h Start of Message C 3 1 D 43h 33h 31h 44h Security Lock Control reply command ST EN Lock condition result data ST Status 0 0 30h 30h No error 0 1 30h 31h Error EN Enable Disable Current condition 0 0 30h 30h Disable 0 1 30h 31h START UP LOCK Enable 0 2 30h 32h CONTROL LOCK 0 3 30h 33h BOTH LOCK ETX 03h End of ...

Page 80: ...ock Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 2 STX C 3 2 C MajorCH MinorCH ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byt...

Page 81: ... Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 2 STX C 3 2 D MajorCH MinorCH ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor I...

Page 82: ... Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Date Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 2 0 STX C B 0 1 0 0 ST BM BD1 BD BT1 BT2 EM ED1 ED2 ET1 ET2 TD ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID...

Page 83: ...h 31h SECOND 02h 30h 32h THIRD 03h 30h 33h FOUR 04h 30h 34h LAST 05h 30h 35h ED2 END DAY2 Day of the week SUNDAY 01h 30h 31h MONDAY 02h 30h 32h TUESDAY 03h 30h 33h WEDNESDAY 04h 30h 34h THURSDAY 05h 30h 35h FRIDAY 06h 30h 36h SATURDAY 07h 30h 37h ET1 END TIME1 Hour 00h 30h 30h 23 32h 33h ET2 END TIME2 Minute 00h 30h 30h 59 35h 39h TD TIME DIFFERENCE 01 00 00h 30h 30h 00 30 01h 30h 31h 00 30 02h 30...

Page 84: ...Write BM BEGIN MONTH JANUARY DECEMBER 01h 30h 31h 12h 31h 32h BD1 BEGIN DAY1 FIRST 01h 30h 31h SECOND 02h 30h 32h THIRD 03h 30h 33h FOUR 04h 30h 34h LAST 05h 30h 35h BD2 BEGIN DAY2 Day of the week SUNDAY 01h 30h 31h MONDAY 02h 30h 32h TUESDAY 03h 30h 33h WEDNESDAY 04h 30h 34h THURSDAY 05h 30h 35h FRIDAY 06h 30h 36h SATURDAY 07h 30h 37h BT1 BEGIN TIME1 Hour 00h 30h 30h 23 32h 33h BT2 BEGIN TIME2 Mi...

Page 85: ...ader SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A replying monitor s ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length 10bytes Message STX 02h Start of Message C B 0 1 43h 42h 30h 31h Daylight Saving Setting Command 0 1 30h 31h Write ST Error Status No Error 00h 30h 30h E...

Page 86: ... 01h 30h 31h Firmware3 02h 30h 32h Firmware4 03h 30h 33h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a firmware version to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 1 1 STX C B 0 2 ST TY MV PP BV1 BV2 BV3 BR1 BR2 ETX BCC CR Header SOH 01h Start of ...

Page 87: ...2 Minor Basic Version2 00h 30h 30h 09h 30h 39h BV3 Minor Basic Version3 00h 30h 30h 09h 30h 39h BR1 Branch Version1 A 41h 34h 31h Z 5Ah 35h 41h BR2 Branch Version1 A 41h 34h 31h Z 5Ah 35h 41h Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 88: ...e ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies receipt result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 A 0 1 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ...

Page 89: ... 89 139 Delimiter CR 0Dh End of packet ...

Page 90: ...plete ST Error Status No Error 00h 30h 30h Error 01h 30h 31h MON DETECTED MONITORS 01h 30h 31h 64h 36h 34h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The controller replies to the monitor Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 A 0 2 ST ETX BCC CR Header SOH 01h Sta...

Page 91: ... 91 139 Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 92: ... code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 A 0 3 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set...

Page 93: ... to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B LN H LN L STX C B 0 4 0 0 Data 0 Data 1 Data 2 Data n ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A replying monitor s ID is 1 B 42h Message type is Command reply LN H LN L Message length byte length ...

Page 94: ...7h 41h VGA Result Input Name is VGA Note No null termination character is sent ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 95: ...acters 2 and 0 32h and 30h Ex In the case of Input Name VGA Step1 Input Name data is handled as character code Example VGA 56h 47h 41h ASCII Step2 The hexadecimal value of each original character is encoded as two ASCII characters representing the value Example 56h 47h 41h 5 6 4 7 4 1 Result The following data is assigned to Data n 35h 36h 34h 37h 34h 31h ETX 03h End of Message Check code BCC Bloc...

Page 96: ... 96 139 ST Status 00h 30h 30h No Error 01h 30h 31h Error ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 97: ... ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 0 0 2 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex Whe...

Page 98: ... 98 139 Delimiter CR 0Dh End of packet ...

Page 99: ...h 30h 33h Auto Tile Matrix Command 0 1 30h 31h Execution HM HORIZONTAL MONITORS 01h 30h 31h 10h 31h 30h VM VERTICAL MONITORS 01h 30h 31h 10h 31h 30h PID PETTERN ID 01h 30h 31h Fixed SEL CURRENT INPUT SELECT VGA 01h 30h 31h DVI 03h 30h 33h VIDEO 05h 30h 35h S VIDEO 07h 30h 37h Y Pb Pr 0Ch 30h 43h OPTION 0Dh 30h 44h Y Pb Pr2 0Eh 30h 45h DPORT 0Fh 30h 46h DPORT2 10h 31h 30h HDMI 11h 31h 31h HDMI2 12h...

Page 100: ...ge type is Command reply 0 A 30h 41h Message length 10bytes Message STX 02h Start of Message C B 0 3 43h 42h 30h 33h Auto Tile Matrix Command 0 1 30h 31h Execution ST Error Status No Error 00h 30h 30h Error 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 101: ...ify ST Error Status No Error 00h 30h 30h Error 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The controller replies to the monitor Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 3 0 2 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiv...

Page 102: ... 102 139 Delimiter CR 0Dh End of packet ...

Page 103: ...h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies H V Monitors to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 E STX C B 0 3 0 4 ST HM VM ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a rep...

Page 104: ... 104 139 Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 105: ...30h 30h 41h VM V MONITORS 00h 0Ah 30h 30h 30h 41h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 3 0 5 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is t...

Page 106: ... 106 139 Delimiter CR 0Dh End of packet ...

Page 107: ... 30h 36h Off ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies receipt result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 3 0 6 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replyi...

Page 108: ... 108 139 Delimiter CR 0Dh End of packet ...

Page 109: ... Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Power Save Mode to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 0 MODE ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID ...

Page 110: ... 110 139 Delimiter CR 0Dh End of packet ...

Page 111: ...ER SAVE 01h 30h 31h AUTO STANDBY 02h 30h 32h POWER SAVE OFF ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 1 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message rec...

Page 112: ... 112 139 Delimiter CR 0Dh End of packet ...

Page 113: ...ge Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 2 TIME ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When t...

Page 114: ...ec 00h 30h 30h 78h 37h 38h 1 5dec 120 600sec ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 8 STX C B 0 B 0 3 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the co...

Page 115: ... 115 139 Delimiter CR 0Dh End of packet ...

Page 116: ...age Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 4 TIME ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When ...

Page 117: ...h 30h 30h 78h 37h 38h 1 5dec 120 600sec ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 5 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the control...

Page 118: ... 118 139 Delimiter CR 0Dh End of packet ...

Page 119: ...ck Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Setting Copy to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 0 STX C B 0 9 0 0 T4 T3 T2 T1 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is ...

Page 120: ...CTURE is OFF 0 Bit2 ADJUST is ON 1 Bit3 AUDIO is ON 1 Step 1 Put above bit in following order Bit3 Bit2 Bit1 Bit0 Value 1100 Step 2 Write the value of Step 1 by a hexadecimal number Value 0Ch Step 3 Encode the value of Step 2 to ASCII characters Value 0 and C 30h and 43h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0D...

Page 121: ...h T1 Setting Copy Target 4 Bit12 Bit15 T2 Setting Copy Target 3 Bit8 Bit11 T3 Setting Copy Target 2 Bit4 Bit7 T4 Setting Copy Target 1 Bit0 Bit3 Bit0 ALL INPUT Bit1 PICTURE Bit2 ADJUST Bit3 AUDIO Bit4 SCHEDULE Bit5 PIP Bit6 OSD Bit7 MULTI DISP Bit8 PROTECT Bit9 EXT CTRL Bit10 ADVANCED Bit11 ADVANCED2 Bit12 HTTP Bit13 Reserve Bit14 Reserve Bit15 Reserve Ex Setting the following value for T4 Bit0 AL...

Page 122: ...ate a replying Monitor ID Ex When this byte is set to A replying monitor s ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length 10byte Message STX 02h Start of Message C B 0 9 43h 42h 30h 39h Setting Copy Reply 0 1 30h 30h Target Write ST Status No Error 00h 30h 30h Error 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a ...

Page 123: ... ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 9 0 2 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monito...

Page 124: ... 124 139 Delimiter CR 0Dh End of packet ...

Page 125: ...h Enable Read ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Security Enable to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 C 0 2 EN ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ...

Page 126: ... 126 139 Delimiter CR 0Dh End of packet ...

Page 127: ...g procedure Ex In the case of password data 1234 Step1 Password data is handled as character code Example 1234 31h 32h 33h 34h ASCII Step2 The hexadecimal value of each original character is encoded as two ASCII characters representing the hex value Example 31h 32h 33h 34h 3 1 3 2 3 3 3 4 Step3 Password data is handled as character code once again Example 3 1 3 2 3 3 3 4 33h 31h 33h 32h 33h 33h 33...

Page 128: ...itor s ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length 10byte Message STX 02h Start of Message C B 0 C 43h 42h 30h 43h Security password Reply Command 0 1 30h 31h Enable Write ST Error Status 00h No Error 01h Error ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 129: ...age Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies MAC Address to the controller Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message Type is Command reply...

Page 130: ... 130 139 In the case of IPv6 n 7 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 131: ...command MD Mode of Proof of Play 0 0 30h 30h Stop 0 1 30h 31h Start 0 2 30h 32h Clear Log data ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result of set Operation mode to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 0 A STX C B 1 5 0 0 ST ETX BCC ...

Page 132: ... 132 139 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 133: ...Message length is 8 bytes Message STX 02h Start of Message C A 1 5 Proof of Play command 0 1 30h 31h Get Current log of Proof of Play command ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result of Current log data to the controller Header Message Check code Delimiter SOH 0 M...

Page 134: ...nput reply parameter Refer to Item AUDIO INPUT on page 33 Data 6 Check with or without Audio 0 0 30h 30h Audio in 0 1 30h 31h No Audio in 0 2 30h 32h N A Data 7 Check status Picture 0 0 30h 30h Normal Picture 0 1 30h 31h No Picture Data 8 Check status Audio 0 0 30h 30h Normal Audio 0 1 30h 31h No Audio Data 9 Data 10 Year h h h h 0 65535 0000h FFFFh Ex 2014 0 7 D E 2014 07DEh Data 11 month 0 1 30h...

Page 135: ...tion Delimiter CR 0Dh End of packet 2 The monitor replies the status of Proof of Play to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 1 4 STX C B 1 5 0 2 ST1 ST2 ST3 ST4 ST5 ST6 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID from which you want to get status Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller...

Page 136: ...Maximum possible number of log data items 0 0 0 0 F F F F 30h 30h 30h 30h 46h 46h 46h 46h 0 65535 ST6 Current Proof of Play status Stop 00h 30h 30h Start 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Page 137: ...f Stop High byte BNE L Block Number of Stop Low byte ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the number to number log of Proof of Play to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 3 4 STX C B 1 5 0 3 LNR H LNR L Data 0 Data 1 Data 2 Data 18 ETX...

Page 138: ...f Message C B 1 5 Proof of Play reply command 0 3 30h 33h Get Proof of Play Number to Number log command LNR H log number being returned High byte LNR L log number being returned Low byte Data 0 Data 12 Log Data of Proof of Play of STOP 26byte Same as Get Proof of Play Current Refer to Get Proof of Play Current ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 3 Check c...

Page 139: ...d This document provides the technical information for users NEC Display Solutions Ltd reserves the right to change or modify the information contained herein without notice NEC Display Solutions Ltd makes no warranty for the use of its products and bears no responsibility for any errors or omissions which may appear in this document ...