background image

 

(1/43) 

External Control                                    NEC LCD Monitor

 

1. Application

 

 

This document defines the communications method for control of the NEC LCD monitor, MultiSync X461UN 

when using an external controller

.

 

 

2. Connectors and wiring 

2.1 RS-232C Remote control 

 

Connector: 9-pin D-Sub 

 Cable: Cross (reversed) cable or null modem cable 

 

(Please refer 

Controlling the LCD monitor via RS-232C Remote control

 on User

s manual.) 

 

2.2 LAN control 

 

Connector: RJ-45 10/100 BASE-T 

 Cable: Category 5 or higher LAN cable 

 

(Please refer 

Controlling the LCD monitor via RS-232C Remote control

 on User

s manual.) 

 

3. Communication Parameter

 

3.1 RS-232C Remote control 

(1) Communication system 

Asynchronous 

(2) Interface 

 

RS-232C 

(3) Baud rate 

 

9600bps 

(4) Data length 

 

8bits 

(5) Parity 

 

None 

(6) Stop bit 

 

1 bit 

(7) Communication code 

ASCII 

 

3.2 LAN control 

Use the payload of TCP packet. 
 

3.3 Communication timing 

The controller should wait for a packet interval before next command is sent. 
The packet interval needs to be longer than 600msec for the LCD monitor.

 

 

 

Summary of Contents for X461UN - MultiSync - 46" LCD Flat Panel...

Page 1: ...2 LAN control Connector RJ 45 10 100 BASE T Cable Category 5 or higher LAN cable Please refer Controlling the LCD monitor via RS 232C Remote control on User s manual 3 Communication Parameter 3 1 RS...

Page 2: ...Check Code Delimiter Get Parameter Reply Save Current Setting Command Get Parameter Header Message Check Code Delimiter The controller sends command to get a value from the monitor that you want to ch...

Page 3: ...36 64h 61 7Dh 86 96h 12 4Ch L 37 65h 62 7Eh 87 97h 13 4Dh M 38 66h 63 7Fh 88 98h 14 4Eh N 39 67h 64 80h 89 99h 15 4Fh O 40 68h 65 81h 90 9Ah 16 50h P 41 69h 66 82h 91 9Bh 17 51h Q 42 6Ah 67 83h 92 9Ch...

Page 4: ...to the section 6 Message format for more detail 1 Get current parameter The controller sends this message when you want to get the status of the monitor For the status that you want to get specify the...

Page 5: ...etc Refer to section 5 5 Commands message for more details 6 Command reply The monitor replies to a query from the controller Command reply message format depends on each command Refer to section 5 5...

Page 6: ...h xor 30h xor 30h xor 36h xor 34h xor 03h 77h 4 6 Delimiter Packet delimiter code ASCII CR 0Dh Header Message SOH Reserved Destination Address Source Address Message type Message length STX OP code pa...

Page 7: ...OP code page Lo ASCII 2 32h Refer to Operation code table Appendix A 4th 5th bytes OP code Operation code Refer to Appendix A Operation code table for each item OP code data must be encoded to ASCII c...

Page 8: ...h is encoded to ASCII character 1 and A 31h and 41h 8th 9th bytes Type Operation type code 00h Set parameter 01h Momentary Like the Auto Setup function which automatically changes the parameter This r...

Page 9: ...yte STX Start of Message ASCII STX 02h 2nd 3rd bytes Result code ASCII 0 0 30h 30h No Error ASCII 0 1 30h 31h Unsupported operation with this monitor or unsupported operation under current condition 4...

Page 10: ...the monitor to store the adjusted value Send OC 30h 43h as Save current settings command Complete Save Current setting command packet as follows ASCII 01h 30h 41h 30h 41h 30h 34h 02h 30h 43h 03h CHK 0...

Page 11: ...0 A A 0 4 STX B E ETX CHK CR 6 Typical procedure example The following is a sample of procedures to control the monitor these are examples of Get parameter Set parameter and Save current settings 6 1...

Page 12: ...ction 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 3 The controller request the monitor to change the Brightness setting Header SOH 01h Start Of Header 0 30h Reserved Monit...

Page 13: ...er Message Check code Delimiter SOH 0 Monitor ID 0 A 0 4 STX 0 C ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved Monitor ID Specify the Monitor ID which you want to store the setting Ex If Mo...

Page 14: ...er is the controller Monitor ID Indicates a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 F 46h Message Type is Set parameter reply 1 2 31h 32h Message length is 18 by...

Page 15: ...Monitor ID is 1 D 44h Message Type is Get parameter reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 0 30h 30h Result code No error 0 2 30h 32h Operation code page numb...

Page 16: ...the current power status Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Mo...

Page 17: ...eader SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message...

Page 18: ...ut data length is 32bytes Secondly set 20h Read data from the 32bytes offset point in the Asset data area Maximum readout length is 32bytes at a time ETX 03h End of Message Check code BCC Block Check...

Page 19: ...s strings ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a data for confirmation...

Page 20: ...st command ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Date Time to the contro...

Page 21: ...his command is used in order to write the setting of the Date Time 1 The controller requests the monitor to write Date Time Header Message Check code Delimiter SOH 0 Monitor ID 0 A 1 2 STX C 2 1 2 YY...

Page 22: ...e monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 6 STX C 3 1 2 ST YY MM DD WW HH MN DS ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30...

Page 23: ...le Read This command is used in order to read the setting of the Schedule 1 The controller requests the monitor to read Schedule Header Message Check code Delimiter SOH 0 Monitor ID 0 A 0 8 STX C 2 1...

Page 24: ...Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn on time minute 0 0 30h 30h 0 3 B 33...

Page 25: ...or a BCC calculation Delimiter CR 0Dh End of packet 10 2 Schedule Write This command is used in order to write the setting of the Schedule 1 The controller requests the monitor to write Schedule Heade...

Page 26: ...0h 37h SCART 0 8 30h 38h VIDEO1 0 9 30h 39h VIDEO2 0 A 30h 41h S VIDEO 0 B 30h 42h OPTION DTV 0 C 30h 43h OPTION COMPONENT 0 D 30h 44h OPTION DIGITAL 0 E 30h 45h OPTION ANALOG WD Week setting bit 0 Mo...

Page 27: ...nitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 1 A 31h 41h Message length Message STX 02h Start of Message C 3 1...

Page 28: ...bit 1 are 1 it behaves as Everyday EX 0 1 30h 31h Disable Everyday 0 4 30h 34h Enable once P MODE Picture mode 0 0 30h 30h HI_BRIGHT 0 1 30h 31h STANDARD 0 2 30h 32h sRGB 0 3 30h 33h CINEMA 0 4 30h 3...

Page 29: ...r ID B 0 C STX C 3 1 5 ST PG EN ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to...

Page 30: ...Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be wri...

Page 31: ...Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the serial No data to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX C 3 1 6 Dat...

Page 32: ...rt Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command...

Page 33: ...2h 31h 44h Security Lock Control command EN P1 P2 P3 P4 Lock condition control data EN Enable Disable 0 0 30h 30h Disable 0 1 30h 31h Enable P1 Security Pass code 1st 0 0 30h 30h 0 0 9 30h 39h 9 P2 Se...

Page 34: ...eply command ST EN Lock condition result data ST Status 0 0 30h 30h No error 0 1 30h 31h Error EN Enable Disable Current condition 0 0 30h 30h Disable 0 1 30h 31h Enable ETX 03h End of Message Check c...

Page 35: ...h Red 9Bh Yellow 9Ch Green 9Dh Cyan 9Eh Blue 9Fh Magenta A0h 0 50 32h center 100 64h Saturation 8Ah 0 pale 10 0Ah deep Gamma Selection 02h 68h Gamma Table Selection 1 Native Gamma 4 Gamma 2 2 8 Gamma...

Page 36: ...0 Left side Max Right side Depends on a display timing V Position 00h 30h 0 Bottom side Max Top side Depends on a display timing Clock 00h 0Eh 0 Max Clock Phase 00h 3Eh 0 Max H Resolution 02h 50h 0 Lo...

Page 37: ...Low 3 High Not available on X461UN Audio Input 02h 2Eh 1 Audio 1 PC 2 Audio 2 3 Audio 3 4 HDMI 5 TV Option AUDIO Menu tree reset Audio 02h CBh 0 None 4 Reset Audio category Momentary Off Timer 02h 2B...

Page 38: ...1 On 2 Off PIP Input Sub input 02h 73h 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 Video1 6 Video2 7 S Video 10 TV 12 DVD HD1 13 Option 14 DVD HD2 15 Display Port 17 HDMI This operation has limi...

Page 39: ...2 Enable On Tile Matrix Mode 02h D3h 1 Disable Off and display frame 2 Enable On 3 Disable Off and erase frame Set only Power On Delay 02h D8h 0 Off 0sec 50 50sec Power Indicator 02h BEh 0 None 1 Off...

Page 40: ...Fh Priority3 10h 30h Priority4 10h 31h Custom Detect Priority5 10h 32h 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 Video1 6 Video2 7 S Video 10 TV 12 DVD HD1 13 Option 14 DVD HD2 15 Display Port...

Page 41: ...V 12 DVD HD1 13 Option 14 DVD HD2 15 Display Port 17 HDMI Audio Input 02h 2Eh 1 Audio 1 PC 2 Audio 2 3 Audio 3 4 HDMI 5 TV A 6 TV D Option Volume UP Down 00h 62h 0 whisper 100 loud Mute 00h 8Dh 0 2 UN...

Page 42: ...limitation of selection Please refer to the monitor instruction manual Still Capture 02h 76h 0 Off 1 Capture Momentary Signal Information 02h EAh 0 No Action 1 Off No indication 2 On Indication TV Cha...

Page 43: ...ument provides the technical information for users NEC Display Solutions Ltd reserves the right to change or modify the information contained herein without notice NEC Display Solutions Ltd makes no w...