Programming
8
◆
Installation
UX Mail Manual
Programming
UX Mail Programming
Basic Setup
16-02-01: D
EPARTMENT
G
ROUP
A
SSIGNMENT
FOR
E
XTENSIONS
Assign the UX Mail extensions to a unique Department Group (e.g.,
2
).
- These are the extensions automatically assigned by the system to the UX Mail blade. The
extensions should be consecutive.
- No other extensions should be in this group.
- Do not use Department Group 1.
- Be sure to set up the Department Group in order. (For example, the first extension should be
order 1, the second order 2, etc.).
✔
By default, all extensions are in Department Group 1.
11-07-01: D
EPARTMENT
G
ROUP
P
ILOT
N
UMBERS
Assign the Pilot Number for the UX Mail Department Group (e.g.,
700
).
✔
By default, there are no Pilot Numbers assigned.
45-01-01: V
OICE
M
AIL
I
NTEGRATION
O
PTIONS
, V
OICE
M
AIL
D
EPARTMENT
G
ROUP
N
UMBER
Enter the Department Group you assigned in step 1 above (e.g.,
2
).
✔
By default, there is no Department Group assigned.
15-03-01: S
INGLE
L
INE
T
ELEPHONE
B
ASIC
D
ATA
S
ETUP
- SLT S
IGNALING
T
YPE
For each UX Mail extension, enter
0
(DP).
✔
By default, this option is 1 (DTMF).
15-03-03: S
INGLE
L
INE
T
ELEPHONE
B
ASIC
D
ATA
S
ETUP
- T
ERMINAL
T
YPE
For each UX Mail extension, enter
1
.
- This allows UX Mail to receive voice mail commands dialed from system extensions.
✔
By default, this option is 0.
15-07-01: P
ROGRAMMING
F
UNCTION
K
EYS
Voice Mail keys are code
77
.
The
additional data
is normally the number of the extension you are programming.
- Keysets can also have Voice Mail keys for Virtual Extensions, a co-worker, or an uninstalled
extension (for Message Center operation).
- Extension users can use Service Code 851 to set up their own Voice Mail keys.
✔
By default, there are no Voice Mail keys assigned.
1.
Assign the UX Mail extension numbers to a unique Department Group.
2.
Assign a master number to the UX Mail Department Group.
3.
Specify the Department Group used for UX Mail.
4.
Set the dialing type to Dial Pulse (DP) for each UX Mail extension.
5.
Set the terminal type for each UX Mail extension.
6.
Program Voice Mail keys on system extensions.
Summary of Contents for UX5000
Page 18: ...Table of Contents xvi Table of Contents UX Mail Manual ...
Page 46: ...Some Common UX Mail Applications 28 Installation UX Mail Manual ...
Page 243: ...Message Retention UX Mail Manual Chapter 2 Features 225 2 ...
Page 313: ...Transfer to an ACD Group UX Mail Manual Chapter 2 Features 295 2 Operation N A ...
Page 328: ...Welcome Message 310 Chapter 2 Features UX Mail Manual ...
Page 361: ...Customize Distribution Lists UX Mail Manual Chapter 3 Programming 343 3 Remove Add List ...
Page 516: ...Reports Mailbox Options Report 498 Chapter 3 Programming UX Mail Manual Subscriber Mailbox ...
Page 528: ...Reports Auto Attendant Trunk Report 510 Chapter 3 Programming UX Mail Manual ...
Page 542: ...Tools Updates 524 Chapter 3 Programming UX Mail Manual Updates Description Not used ...