![NEC UNIVERGE UM8500 Integration Manual Download Page 235](http://html.mh-extra.com/html/nec/univerge-um8500/univerge-um8500_integration-manual_251655235.webp)
NEC UNIVERGE SV8300
USING
OAI
225
Programming
the phone
system
If programming options other than those supplied in the following procedures are
used, the integration’s performance might be affected.
To set the Message Center Interface (MCI) configuration
Verify the following configurations and settings.
1
Verify that t
he 9800,8,n,1 serial communication parameter settings are set
as described in the table below. If a parameter is not the same, change it to the
setting in the table.
To set the OAI configuration
Verify the following configurations and settings.
1
Verify that t
he IP Address is set per the phone system configuration,
Example 172.16.19.61.
2
Verify that t
he Subnet mask is set per the phone system configuration,
Example 255.255.255.0.
3
Add the non-default extensions lines (non-default hardware LENS): 224-239.
4
Verify that t
he OAI pilot is set per the phone system configuration, for
example 299.
5
Verify that t
he monitored extensions or voice ports are set per the phone
system configuration, for example 208-231.
6
Verify that t
he monitored DTerm Function Keys on extension 201 set per
the phone system configuration, for example 09-12 (function codes F1032-
F1035; Terminal Mode Facility codes 192-195).
NOTE
The following procedures are written with the assumption that you
will use the SV8300 PCPro software to enter the settings presented
in the procedures.
IMPORTANT
Only adjust the MCI settings if the OAI UCD with Serial MCI
integration is being used.
Command
Description
0401>01>0
Connection port for MCI = 0
08>708>0
MCI extension length = 6 (!)
08>025>0
Message indication = MESSAGE
08>443:1-0
Set the type of VMS integration: MCI (0) instead of
DTMF (1) (!)
4000>0>10
Function = MCI
4001>0>1
Data length = 8 bit
4002>0>1
Parity check = Ineffective
4004>0>0
Stop bit = 1
4008>0>4
Data speed = 9600 bps
Summary of Contents for UNIVERGE UM8500
Page 1: ......
Page 28: ...UNIVERGE UM8500 INTEGRATION GUIDE 18 ...
Page 62: ...UNIVERGE UM8500 INTEGRATION GUIDE 52 ...
Page 68: ...UNIVERGE UM8500 INTEGRATION GUIDE 58 ...
Page 94: ...UNIVERGE UM8500 INTEGRATION GUIDE 84 ...
Page 104: ...UNIVERGE UM8500 INTEGRATION GUIDE 94 ...
Page 114: ...UNIVERGE UM8500 INTEGRATION GUIDE 104 ...
Page 120: ...UNIVERGE UM8500 INTEGRATION GUIDE 110 ...
Page 126: ...UNIVERGE UM8500 INTEGRATION GUIDE 116 ...
Page 146: ...UNIVERGE UM8500 INTEGRATION GUIDE 136 ...
Page 164: ...UNIVERGE UM8500 INTEGRATION GUIDE 154 For a SPADLIC A trunk board ...
Page 172: ...UNIVERGE UM8500 INTEGRATION GUIDE 162 ...
Page 188: ...UNIVERGE UM8500 INTEGRATION GUIDE 178 ...
Page 193: ...NEC NEAX 2400 OR NEC SV7000 WITH LAN MCI 183 For a SPADLIC A trunk board ...
Page 222: ...UNIVERGE UM8500 INTEGRATION GUIDE 212 ...
Page 230: ...UNIVERGE UM8500 INTEGRATION GUIDE 220 ...
Page 276: ...UNIVERGE UM8500 INTEGRATION GUIDE 266 ...
Page 290: ...UNIVERGE UM8500 INTEGRATION GUIDE 280 ...
Page 302: ...UNIVERGE UM8500 INTEGRATION GUIDE 292 ...
Page 312: ...UNIVERGE UM8500 INTEGRATION GUIDE 302 ...
Page 336: ...UNIVERGE UM8500 INTEGRATION GUIDE 326 ...
Page 342: ...UNIVERGE UM8500 INTEGRATION GUIDE 332 ...