Chapter 3 REMOTE UNIT OVER IP FEATURES
3-50
NWA-088654-001 Rev.1.0
94ch3001.fm
SETUP THE SYSTEM
SETUP THE SYSTEM
After the system data programming in
, follow the procedure be-
low. (The two routers should already be working correctly.)
STEP1:
Turn power switch of the Main Unit on.
STEP2:
Confirm that the CPU in Main Unit is working, and turn power switch of the Remote Unit on.
– The communication between Main Unit and Remote Unit starts.
STEP3:
Confirm that the system data has been copying from Main Unit to Remote Unit.
– After 30 seconds, the RUN LED on CPU blade at Remote Unit flashes at 30 IPM.
STEP4:
Confirm that the system data is backed up in Flash ROM of CPU blade at Remote Unit.
– SYSD LED on the CPU blade turns on, and the data back up starts. (It takes two minutes to
back up the system data.)
STEP5:
Confirm that Normal Mode operation starts.
– The CPU blade in the Remote Unit resets itself automatically, and starts Normal Mode oper-
ation.