Chapter 3 REMOTE UNIT OVER IP FEATURES
3-33
NWA-088654-001 Rev.1.0
94ch3001.fm
TIME ZONE/DAYLIGHT SAVING TIME DATA ASSIGNMENT
TIME ZONE/DAYLIGHT SAVING TIME DATA ASSIGNMENT
To enable remote connection of stations regardless of nation and area with multiple time zone, do the fol-
lowing programming.
DESCRIPTION
DATA
Assign the Location number to each Unit.
NOTE 1:
This data is available when location
number is not assigned by CM12
Y=39, 50.
NOTE 2:
When standard SIP terminal is ac-
commodated, assign location num-
ber for VoIPDB by this command.
•
(1)
(2)
Y=1XX (VOIP Port [1] + Unit No. [02-50])
10
00-63
: Location No. 00-63
NONE : Location No. 00
Assign the Time Zone to the location number
assigned by CM0B Y=1XX>10.
•
(1)
(2)
Y=10
00-63: Location No. 00-63
Time Zone (See the table below)
NONE : No Time Zone
NOTE 1:
System clock should be assigned by CM02.
NOTE 2:
After changing the data, system data copying to Remote Unit by CMEC Y=8 is required.
START
CM0B
CM67
+15 minute increments
2nd Data
Time Zone
A2345
System Clock +23:45
A2330
System Clock +23:30
A2315
System Clock +23:15
A2300
System Clock +23:00
A0100
System Clock +01:00
A0045
System Clock +00:45
A0030
System Clock +00:30
A0015
System Clock +00:15
NONE
No Time Zone (No time
difference)
-15 minute increments
2nd Data
Time Zone
B0015
System Clock -00:15
B0030
System Clock -00:30
B0045
System Clock -00:45
B0100
System Clock -01:00
B2300
System Clock -23:00
B2315
System Clock -23:15
B2330
System Clock -23:30
B2345
System Clock -23:45
CCC
Time Zone data clear
A