Program 47 : InMail
47-02 : InMail Station Mailbox Options
Level:
IN
Description
Use
Program 47-02 : InMail Station Mailbox Options
to set up a station/extension mailbox. Station
mailboxes are automatically assigned as Subscriber Mailboxes. Normally, InMail Station Mailbox
numbers 1 ~ 64 should correspond to extensions 101-164.
Station Mailboxes are one of three mailbox categories: Station, Routing, or Master. You can also set up
Master Mailboxes as Subscriber Mailboxes.
Input Data
Station Mailbox Number
1 ~ 128
Item
No.
Item
Input Data
Description
Default
01
Mailbox Type
0 = None
1 = Personal
2 = Group
Use this option to enable or disable the
mailbox. An extension mailbox is not ac-
cessible when it is disabled (even though
its stored messages and configuration are
retained in memory.) If disabled, a user
pressing
Message
initiates a remote logon
and is asked to enter their mailbox num-
ber. A voice prompt then announces: “That
mailbox does not exist.”
To make programming easier, consider as-
sociating a mailbox number with a station
port. For example, mailbox 1 could corre-
spond to port 1, which in turn corresponds
to extension 101.
Mailbox 1 ~ 64 =
1
Mailbox 65 ~ 256
= 0
02
Mailbox Number
Up to eight digits
Use this option to select the extension
number associated with the mailbox you
are programming. Normally, mailbox 1
should use Mailbox Number 101, mailbox
2 should use Mailbox Number 201, 101
etc.
To make programming easier, consider as-
sociating a mailbox number with a station
port. For example, mailbox 1 could corre-
spond to port 1, which in turn corresponds
to extension 101.
Mailbox 1 = 101
Mailbox 2 ~ 64 =
102 ~ 164
Mailbox 65 ~
256= No Setting
03
Number of Messages
0 ~ 99 messages
To conserve storage
space, enter 0 for all un-
used mailboxes.
Use this option to set the maximum num-
ber of messages that can be left in the
Subscriber Mailbox. If a caller tries to
leave a message after this limit is reached,
they hear : “That mailbox is full.” InMail
then hangs up.
Mailbox 1 = 99
Mailbox 2 ~ = 20
04
Message Playback
Order
0 (FIFO = first-in/ first-
out, or oldest messages
first).
1 (LIFO = last-in/ first-
out, or newest messages
first)
Use this option to set the Subscriber Mail-
box message playback order. When a sub-
scriber listens to their messages, InMail
can play the oldest messages first (first-in/
first-out, or FIFO), or the newest messag-
es first (last-in/first-out, or LIFO).
0
ISSUE 2.0
SL2100
Programming Manual
2-447
Program
47
Summary of Contents for UNIVERGE SL2100
Page 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Page 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Page 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Page 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Page 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Page 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Page 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Page 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Page 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Page 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Page 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Page 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Page 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Page 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...
Page 677: ...MEMO ISSUE 2 0 SL2100 Programming Manual 2 653 ...