2.
Connect the cables from the NT1 Network Termination cable to the J2 or J3 connector on the
2BRIDB-C1 daughter board.
Connector J2 - BRI1: Use switches J12, J13, J14
Connector J3 - BRI2: Use switches J15, J16, J17
Ensure that you set all switches correctly for each BRI circuit.
BRI 1
BRI 2
J12
ON
OFF
J15
ON
OFF
J13
T
S
J14
T
S
J16
T
S
J17
T
S
IP7WW-2BRIDB-C1
J2
J12
J15
J13
J14
J17
J16
Figure 2-71 Switches Location of 2BRIDB-C1
3.4.8 Cabling and Setting IP7WW-1PRIDB-C1
The E1 standard may differ from country by country. The conformity test must
be required before setting the E1 Trunk.
This IP7WW-1PRIDB-C1 board provides one RJ-45 PRI/T1/E1 connection.