– 859 –
NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE TITLE:
BILLING MEMORY CLEAR FOR PN-AP00-B WITH
AP00 PROGRAM
D102
FUNCTION:
This command is used to clear the memory for billing and to load the assigned data for call record when
using PN-AP00-B with AP00 program.
PRECAUTION:
(1) After billing system data all clear is executed by CMD101, assign the system data in the following
order.
STEP 1:
Make the AP00 card OFF LINE by switch setting as shown below.
STEP 2:
CMD001>179
STEP 3:
CMD003>23, 24, 25, 26, 28, 29, 30
STEP 4:
CMD102>0000: CCC
STEP 5:
Make the AP00 card ON LINE by switch setting as shown below.
STEP 6:
Flip the MB switch on the AP00 card to ON (UP position), then OFF (DOWN position).
AP OFF LINE
SW1
ON
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31
4
3
2
1
: Position to be set
SW1
ON
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31
4
3
2
1
: Position to be set
CMD102
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008844 001 ISSUE 5 0 Command Manual ...
Page 24: ... viii NWA 008844 001 Rev 5 0 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...
Page 46: ... 22 NWA 008844 001 Rev 5 0 91ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Page 66: ... 42 NWA 008844 001 Rev 5 0 91ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Page 908: ... 884 NWA 008844 001 Rev 5 0 91ch3009 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 01 2007 ...
Page 988: ... 964 NWA 008844 001 Rev 5 0 91ch4001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Page 1012: ... A24 NWA 008844 001 Rev 5 0 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...