– 712 –
CHAPTER 7
Maintenance Commands
Note:
If the data for this command is assigned, the node-level data by the ATRF command is not cleared, but
loses its validity (the network-level data takes precedence).
Note 1:
When time difference exists between the nodes, confirm that the related time difference data, based on
Universal Coordinated Time (UCT) standard, has been assigned at each node via ATDF command.
Note 2:
Assign the traffic measurement time period between Start TIME and End TIME longer than an hour.
Also, if the measurement should be executed throughout a day, assign the same data in both Start TIME
and End TIME parameters.
Note 3:
ATT Answer Peg Count is available for the following Attendant Incoming Calls. Note that the Route
Class Data (CDN 6: TCL) of the Incoming Route must be 1 (=DDD Line)/2 (=FX Line).
•
Ringdown
•
LDN Call via ISDN/MFC Line.
Furthermore, there are several conditions described below.
(a) The call terminated to the Attendant on the ground from ISDN trunk when Called Number and Sub
Address cannot be received.
(a) In the case of following Incoming Call from ISDN/MFC line to Attendant Console, these services are
not available.
•
Call Forwarding-Busy Line/All Calls/Don’t Answer to Attendant Console.
•
Call Forwarding to Attendant Console by Vacant number.
•
Incoming Call to Attendant Console with All Attendant Access from trunk.
•
Incoming Call to Attendant Console with Individual Attendant Access.
•
Incoming Call to Attendant Console with Remote Access to System.
Note 4:
To activate Station Peg Count, ATTCON Peg Count and Service Peg Count, assign the largest value of
Number of Tenants (ASYDN, SYS1, INDEX 8) in all nodes. Assign “FF Hex” for MDATA.
Note 5:
To activate ATTCON Peg Count and ATT Answer Peg Count, assign the largest value of Number of
Attendant Consoles (ASYDN, SYS1, INDEX 9) in all nodes. Assign “FF Hex” for MDATA.
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......