– 108 –
CHAPTER 2
Operations of SV8500 Server
8.1.6
Manual Changeover of PLO
This section explains how to changeover Phase Lock Oscillator (PLO) card, which can be switched over
independently of Speech Path System.
Changeover of PLO (1-IMG
)
STEP 1
Make sure which PLO is currently placed in ACT mode.
When PLO is active, PLO ACT lamp on the TSW circuit card lights green. If PLO ACT lamp
is off, the PLO is in STBY mode.
Changeover of PLO (1-IMG)
TYPE
OPERATIONS
REMARKS
Changeover by key operation
- Set PLO MBR key upward on the TSW
whose PLO is placed in ACT.
- Make sure that PLO ACT lamp goes off on
the card, and PLO ACT lamp lights green on
the mate PLO-STBY-TSW card.
- Return TSW MBR key downward on the
key-operated-TSW card.
- PLO ACT lamp goes off when PLO MBR key is set up-
ward on the TSW whose PLO is placed in ACT.
- PLO ACT lamp lights green on the mate PLO-STBY-
TSW card.
Target Cards for Manual System Changeover of PLO (1-IMG)
MODULE
SLOT
NUMBER
CIRCUIT CARD
TARGET CARD LOCATION
PIR0
13
TSW
(PH-SW10-A, etc.)
14
TSW
(PH-SW10-A, etc)
Improper key operations may result in a system down. Operate the related keys with extreme
care.
WARNING
Voice calls are not be affected by PLO changeover. However, bit errors may occur on data
lines.
WARNING
13 14
TSW0
TSW1
FANU
PIR0
SV8500 Server
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......