– 76 –
CHAPTER 2
Operations of SV8500 Server
6.2 EMA Card Replacement Procedure
EMA card is mounted in the telephony server. The main functions of the card are as fol-
lows:
•
Designation of ACT/STBY status of the CPU
•
Detection of abnormality within the system
•
Control of the PFT (NCU) circuit card
Note:
Power Failure Transfer (PFT) will be activated during EMA card replacement when PFT is provided.
[Start]
STEP 1
Loosen the screws from the EMA card.
STEP 2
Pull the EMA card toward you slowly to remove from the system.
Note:
PFT function will start operating if NCU circuit card is provided.
STEP 3
On the new EMA card, set the switches exactly same as those of the old EMA card.
STEP 4
Insert the new EMA card to the system. (Insert the connector to the system firmly.)
•
PWR lamp lights green on the front panel of the EMA card.
STEP 5
Fasten the new EMA card with the screws.
Note:
PFT function will stop operating automatically.
STEP 6
Set the clock information referring to “
[End]
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
CPU card #1
SV8500 Server (front)
CPU card #0
EMA card
IOC card (Option)
IOC card (Option)
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......