– 62 –
CHAPTER 2
Operations of SV8500 Server
5.4 INITIALIZATION PROCEDURE OF CF CARD
5.4.1
Procedure For FP85-104 S1E
This section explains how to initialize CF card. Performing this procedure, all the contents on the card will
be initialized, leaving BASE System (OS) only installed. Any programs of the system, SVI files, or office
data settings are not to be installed on the card. To install these data to CF card, perform the initial instal-
lation by using PCPro Tools after this initialization procedure.
Note:
Refer to the “Installation Manual”
o
”CHAPTER 5 SYSTEM STARTUP”
o
“1.2 Program Install to CF
Card” for the initial installation procedures.
Note 1:
Keyboard can be selected whether Japanese keyboard layout or English keyboard layout.
Note 2:
Initialization procedures delete all the programs, SVI files, and office data settings from the CF card.
Be sure to make backups of these data before performing the following steps.
Note 3:
Performing the initial installation procedures and executing reboot, LAN1 becomes invalid. Set LAN1
by using PCPro Tools.
Note 4:
During the initial installation procedure, the default IP address of LAN1 is set to 192.168.0.2. Check
the settings on your PC. After the initial installation process, the default IP address for LAN2 of
SV8500 becomes 172.16.253.0/16. Check the settings on your PC.
Note 5:
Use DISS command to check the issue information of BASE System (OS). You can see the issue infor-
mation of the installer CD-ROM printed on the label as “BASE_SYS:xx.xx”. When you obtain the latest
installer CD-ROM, compare the version information and decide whether to update the OS or not.
Note 6:
You do not have to specify a correct device of boot prompt in normal.
Note 7:
You do not have to do mounting CD/DVD drive operation.
Initialization procedure deletes all the programs, SVI files, and office data settings from the CF
card. Be sure to make backups of these data before performing the following steps.
WARNING
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......