VOL.2-2126
SR-MGC(S)
26.5 Startup
This section describes the procedure to start up an SR-MGC(S).
SR-MGC(S) Startup Procedure
For details on hardware information, see
STEP 1: Turn on an SR-MGC(S).
Turn on power of an SR-MGC(S), where its operation is the following: booting up the system; reading
default office data.
Note:
An IP address set in default office data is 172.16.253.0/16.
STEP 2: Check lamps.
Make sure that lamp states are as follow.
PWR: ON (green)
ONLINE: Slow flash (green)
Note:
After turning on an SR-MGC(S), it will take about five minutes for the lamps to turn to the preceding
states.
STEP 3: Connect PCPro (PC) outside your LAN.
Connect a PC with PCPro installed to the SR-MGC(S) through the Ether1 connector on it, so that you can
assign office data to the SR-MGC(S).
Note:
If connecting them directly, use a LAN cable (crossover cable); if connecting via a HUB, use LAN cables
(straight-through cables).
STEP 4: Configure PCPro.
Set data to connect PCPro to the SR-MGC(S).
[PCPro Connection Account Setting]
On the Main Menu, click on System; click on Connection Account Setting; set the following.
Account Name
Connection Type: TCP/IP
TCP/IP Setting
IP Address: 172.16.253.0, a default IP address of an SR-MGC(S)
Port Number: 60000
[PC Setting]
A PC with PCPro needs to have an IP address, subnet mask, and default gateway address set as follow.
After you finish setting, restart the PC.
IP address: 172.16.253.253
Subnet mask: 255.255.0.0
Default gateway address: 172.16.253.0, a default IP address of an SR-MGC(S)
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...