VOL.2-2063
VS-32(Dual) [SCA-VS32VA/MG-VS32VA]
F
To directly enter the setting value:
•
When P1=TOS is entered:
•
When P1=DIFFSERV is entered:
•
When P1=CLEAR is entered to delete the current QoS setting:
Note:
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
mand.
Note:
The value in ( ) shows the current setting.
13. Setting IP address, port number, and host name of SIP server:
This command is used for SIP mode only.
Note:
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
mand.
VS-32(SIP)>
SET SIGNALING_QOS TOS 0xC0
P1
: Enter TOS to set IP Precedence data value
P2
: Enter the setting value [0x02~0xFF]
Signaling QoS setting succeeded.(0xC0)
Result is shown.
VS-32(SIP)>
SET SIGNALING_QOS DIFFSERV 48
P1
: Enter DIFFSERV to set Diffserv data value
P2
: Enter the DSCP setting value [0~63]
Signaling QoS setting succeeded.(0xC0)
Result is shown.
VS-32(SIP)>
SET SIGNALING_QOS CLEAR
P1
: Enter CLEAR to clear QoS setting
Signaling QoS clearing succeeded.(0x00)
Result is shown.
VS-32(SIP)>
SET SIPSV_IPADDRESS
SIP Server (1-20):
1
Enter the SIP server’s number [1-20]
Up to 20 SIP servers can be used in one network.
IP Address:
10.41.1.150
Enter the IP address of SIP server.
e.g. 10.41.1.150 (default=0.0.0.0)
Port Number:
5060
Enter the port number [1024-65535] (default=5060)
Is there the Host Name? (Y/N) [N]:
y
Select whether to use host name [Y/N]
Host Name:
SVR1.nec.com
Enter the host name in the full-domain format, within 63-
byte of alphanumerics, “. (period)”, and “- (hyphen)”.
63. (*This line is displayed when “Y” is selected above.)
SIP server setting succeeded.
Result is shown.
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...