VOL.2-1732
MG-SIP16
Note:
-
Assign this command adjusting to the specifications on SIP network.
-
This command is available for SP-3843 SIPMG PROG-B Issue 6 or later.
-
For the earlier versions of firmware, the command displays as follows. P-Called-Party is not available.
When isub parameter is enable, the called number is obtained from isub of URI-PARAM in Request-URI.
If the called number cannot be obtained from isub, it will be obtained from TO header or Request-URI
that has been set in Config.
8
SET
Δ
CHECK_NUMBER
This command is used to assign a limit to number of digits for calling/called party number (since version
09.00.00.00).
Calling/called party number sent via the Telephony Server network may be limited to numbers only.
Note:
Assign this command adjusting to the specifications on SIP network.
1
isub
P-N-Dest-
Discern
Request-URI
(isub)
Request-URI
(userinfo)
To (userinfo)
-
2
Request-URI
P-N-Dest-
Discern
Request-URI
(userinfo)
Request-URI
(isub)
To (userinfo)
-
3
P-Called-Party-
ID
P-Called-
Party-ID
(userinfo)
To (userinfo)
Request-URI
(userinfo)
P-N-Dest-
Discern
Request-URI
(isub)
MG(SIP) > set cdn_pattern
Active called-party-number?
(0:To:userinfo/1:isub/2:Request-URI/3:P-Called-Party-ID(default=0)):0
• Select a type to obtain
called number information.
0: userinfo part of the To
header is given priority
(Default)
1: isub of Request-URI is
given priority
2: userinfo part of
Request-URI is given
priority
3: userinfo part of P-
Called-Party-ID is
given priority
MG(SIP) > set cdn_pattern
Active called-party-number?(0:To:userinfo/1:Request-URI(default=0)):0
isub function (0:disable/1:enable(default=0)): _
• Select a type to obtain
called number information.
• Priority is selected for the
isub parameter of URI-
PARAMS.
MG(SIP) > set check_number
Is this function enable or disable?
(0:disable/1:enable(default=0)): _
• Enter 0 or 1 (default=0).
0 = Disable (default)
• 1 =Limit to numbers only
Selected Parameter
Order of priority
1
2
3
4
5
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...