VOL.2-1609
MG-SIP96
When you have finished, the following message appears on the Maintenance Console.
Note:
Both LAN1 and LAN2 must be connected to make MG-SIP96 online. (For a one-port configuration,
only LAN1 connection makes MG-SIP96 online.)
Step6:
Checking the lamp status of LINK and SPEED at Ether1 and Ether2 of MG-SIP96
If the connection is established, the following LINK lamps of MG-SIP96 will light green in a few min-
utes.
Note:
For a one-port configuration, LINK lamp at Ether 2 connector does not light.
• Ether1 connector on LAN side: LINK lamp
• Ether2 connector on WAN side: LINK lamp
[SPEED lamp is lighting in orange]
• The MG-SIP96 connects to a network with transmitting speed of 1Gbps.
[SPEED lamp is lighting in green]
• The MG-SIP96 connects to a network with transmitting speed of 100Mbps.
If you expected transmitting speed of 1Gbps, check a connected network device and a cable be-
tween them.
[SPEED lamp is not lighting]
• The MG-SIP96 connects to a network with transmitting speed of 10Mbps.
If you expected transmitting speed of 1Gbps or 100Mbps, check a connected network device and a
cable between them.
Step7:
Checking the lighting of ONLINE lamp.
If the settings are correct, ONLINE lamp of MG-SIP96 lights in green.
19.3.5 Operation Check
Make sure the MG-SIP96 is in normal operation by the following procedure.
Step1:
When the configuration settings are completed, reboot the MG-SIP96 by using “reboot”
command.
Step2:
Make sure the following message appears on the Maintenance Console after rebooting.
*****************************************
*
MG(SIP) ONLINE START
*
*****************************************
*****************************************
*
MG(SIP) ONLINE START
*
*****************************************
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...