12.4.4 How to Upgrade Firmware by FTP (Remote Download)
This upgrading process can be performed on up to eight MG(BRI)s at once.
- Firmware for upgrade
- PCs have to belong to the same segment with MG(BRI).
- FTP server has to be installed in advance.
- PCPro has to be installed in advance.
- MG(BRI) is already registered to system and it is working normally.
<Data Assignment on FTP Server>
STEP 1
Put the firmware file (mgbri-bsc.bin), DSP program file (mgbri-dsp.bin), and download list
file (mgbrisiplist.txt) for upgrade in the root folder of FTP server. They are included in SP ver-
sion name folder [e.g. SP3826].
STEP 2
Allow read in this directory. For more information, refer to the appropriate manual attached to
the FTP server program.
STEP 3
Set network environment for the FTP server.
STEP 4
Start the FTP program.
<Resetting MG-BRI(SIP) by AMGIL Command>
STEP 5
Activate the AMGIL command, and then input the MG-ID of MG-BRI(SIP) to reset.
STEP 6
Click [Get] to read out the registered information.
STEP 7
Select an item of Reset in FUNCTION.
STEP 8
Select an item of Activate in operation mode in Operation after reset.
STEP 9
Click [Execute]. A message window will appear, and then click [Yes].
Note:
Reset all the MG-BRI(SIP) to update, and check they has all been activated normally by using the DIPI
command.
IP Network
FTP Server
PCPro
SYSTEM
MG(BRI) Card/Box
(3) Download firmware via FTP
Firmware
(2) Make environment setting for firmware upgrade
(
1) Make environment setting for FTP
B
D
B
D
ALM
PWR
ON
LINE
EMA TEL
LINE0
LINE1
Ether
100M LINK
CONSOLE
RESET
MUSIC
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...