12.4 Operation and Maintenance
This section explains the operation and maintenance procedure of MG(BRI). Configuration data is assigned by
using Maintenance Console (PC).
12.4.1 How to Restore Config Data by Serial Connection (Local Download)
This config download/upload is performed one by one, connecting a PC to each MG(BRI) with a RS-
232C and a LAN cable. Prepare the following:
- RS-232C cable is required.
- Serial terminal emulation program (such as HyperTerminal) is required
- LAN cable (crossover) is required for restoring config data.
- PCPro has to be installed in advance.
•
Backing Up Config Data By Serial Connection
STEP 1
Power off MG(BRI) and disconnect it from the network.
STEP 2
Connect PC to MG(BRI) by using RS-232C cable.
STEP 3
Power on MG(BRI).
STEP 4
Activate HyperTerminal and set the following:
Bit per second:9600bps
Data bits:8bit
Parity:None
Stop bit:1bit
Flow control:None
STEP 5
Select
[Transfer]
->
[Capture File...]
.
STEP 6
Send File screen is displayed. Specify a file name to be saved, and then click the Start button.
STEP 7
At the moment that boot programming is starting (While “
Starting MG-BRI boot pro-
gram
” is being displayed for approximately five seconds), press the ESC key.
STEP 8
After <Boot mode> Main menu is displayed, enter “1” (Configuration Data).
STEP 9
After <Configuration mode> Main menu is displayed, enter “2” (Custom).
STEP 10
After a prompt (
MG-BRI>
) is displayed, enter “show config” to display configuration data
of the MG(BRI).
STEP 11
Select
[Transfer]
->
[Capture Text]
->
[Stop]
to save the config file shown in screen.
B
D
B
D
ALM
PWR
ON
LINE
EMA TEL
LINE0
LINE1
Ether
100M LINK
CONSOLE
RESET
MUSIC
Serial Console
MG(BRI) Card/Box
RS-232C cable
Configdata
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...