Chapter 1 MAINTENANCE SERVICES
1-30
NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT REPORT SCHEDULING
Programming Procedure
(1) To set a periodic maintenance reminder, do the following programming:
(2) To clear the alarm, do the following programming:
DESCRIPTION
DATA
Assign the date and time setting for periodic
maintenance.
•
(1)
(2)
Y=2
00-07
:
Periodic maintenance
YYYY MM DD HH
YYYY: 2010-2099 (Year)
MM :
01-12 (Month)
DD
:
01-31 (Date)
HH
:
00-23 (Hour)
Assign the check item for periodic mainte-
nance.
•
(1)
(2)
Y=3
00-07
:
Periodic maintenance
0 :
Battery check
1-7:
Check item No. 1-No. 7
Specify the Multiline Terminal for alarm
display, if required.
•
(1)
(2)
Y=16
01: Multiline Terminal No. 1
02: Multiline Terminal No. 2
X-XXXXXXXX: My line number of
Multiline Terminal
Assign the alarm indication key to Multiline
Terminal function key, if required.
•
(1)
(2)
Y=00
My Line No. +
+Key No.
F5020:
Alarm display
Set the alarm kind for periodic maintenance.
•
(1)
(2)
Y=2
016
1: MN alarm
2: MJ alarm
DESCRIPTION
DATA
Clear external alarms.
•
(1)
(2)
Y=1
00 : Clear all of MJ/MN/-- alarms
CCC: Alarm clear
START
CM43
CM51
CM90
,
CMEA
END
START
CMEA
END
APRIL/16/2010