Chapter 1 MAINTENANCE SERVICES
1-19
NWA-033627-001 Rev.4.0
95ch1001.fm
BATTERY RELEASE CONTROL
Operating Procedure
(1) To disconnect the battery
(2) To reconnect the battery
DE
+
EC0>
EC0
ST
COMMAND=
DE
+
EC0>00:1 –
00
EXE
+
EC0>00:1 – 0
0
OK
For the first data, specify the desired unit (01 to 50)
whose battery is to be disconnected. To specify
Unit 01,02,03 and 04 collectively, enter 00.
When the first data is entered, the current status of the
specified unit is displayed. (1: Normal operation)
Enter 0 for the second data to disconnect.
DE
+
EC0>
EC0
ST
COMMAND=
DE
+
EC0>00:0 –
00
EXE
+
EC0>00:0 – 1
1
OK
For the first data, specify the desired unit (01 to 50)
whose battery is to be reconnected. To specify
Unit 01,02,03 and 04 collectively, enter 00.
When the first data is entered, the current status of the
specified unit is displayed. (0: Battery released)
Enter 1 for the second data to reconnect.
APRIL/16/2010