3-663
NWA-033623-001 Rev.8.1
91ch3008.fm
COMMAND CODE TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
FUNCTION:
This command is used for fault maintenance of the PBX. The functions of this command are outlined
below:
• Storing fault information into the Fault Store Memory upon occurrence of a fault.
• Display of the stored fault information
• Control of the external alarm upon occurrence of a fault
PRECAUTION:
(1) In CMEA Y=0, the fault information is automatically displayed when
is pressed after entering
first data 00.
(2) See Fault Information Display in the following pages for details on how to read the fault
information.
(3) When entering data with characters, the following characters can be registered;
Alphabet upper case (A-Z), alphabet lower case (a-z), numeric (0-9), symbol (! “ # $ % & ’ ( ) + ,
; < = > ? @ [ ] ^ _ ‘ { } ~), Space, hyphen (-), period (.), slash (/), colon (:)
NOTE:
The character “CCC” cannot be registered.
ASSIGNMENT PROCEDURE:
DATA TABLE:
DE
ST + EAY
+
+ DE
1ST DATA
(1-3 digits) +
2ND DATA
DE
(1-8 digits)
+
EXE
+
Y
1ST DATA
2ND DATA
RELATED
COMMAND
No.
MEANING
DATA
MEANING
DATA
MEANING
0
Fault information
display
(Display only)
0
9
F
The newest fault information
(0-9) stored in Fault Information
Memory
NOTE 1
Fault information all clear
NOTE 4
–
–
Continued on next page
~
NOVEMBER/12/2008
CMEA
Summary of Contents for SV8300
Page 1: ...Command Manual NWA 033623 001 ISSUE 8 1 ...
Page 8: ...vi NWA 033623 001 Rev 8 1 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...3 716 NWA 033623 001 Rev 8 1 91ch3008 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...
Page 804: ...A 32 NWA 033623 001 Rev 8 1 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...