Program
20
Program 20 : System Option Setup
20-01 : System Options
Level
IN
Description
Use
Program 20-01 : System Options
to set various system options.
Input Data
Item
No.
Item
Input Data
Default
Description
Related Pro-
gram
01
Operator Access
Mode
0=Step Call
1=Circular
0
Use this program to set up
priority of a call when calling
an operator telephone.
20-17
02
Text Message Mode
0=Call mode
1=No Answer/Busy
mode
0
Use this program to select the
mode when calling the tele-
phone which set up the text
message.
11-11-14
15-07-08
04
Network BLF
Indication
0-64800 in 100ms
increments
0
Used to determine how often
the SL1000 updates the DSS
key BLF indications.For
NetLink, the entry should be
05
DTMF Receive Ac-
tive Time
0~64800s
10s
For OPXs, analog telephones
and certain analog trunks (like
DISA), the system attaches a
DTMF receiver to the port for
this time. The system releases
the receiver after the time
expires.
25-07-01
06
Alarm Duration
0~64800s
30s
This time sets the duration of
the alarm signal.
11-11-12
07
Callback Ring Dura-
tion Time
0~64800s
15s
Callback rings an extension
for this time.
11-12-05
15-07-35
08
Trunk Queuing Call-
back Time
0~64800s
15
Trunk Queuing callback rings
an extension for this time.
11-12-05
15-07-35
09
Callback/Trunk
Queuing Cancel
Time
0~64800s
64800s
The system cancels an exten-
sion Callback or Trunk
Queueing request after this
time.
11-12-05
15-07-35
10
Trunk Guard Timer
0~64800s
1
The amount of time the sys-
tem waits to seize the next
outside line after the system
releases an outside line.
12
Telephone/Web Pro
Logout Time
1~84600s(84600s
=1 day)
900s (15min)
The system automatically logs
out of a Telephone/Web Pro
session after inactivity lasting
this time.
16
Mobile Extension
Callback time
1-64800(sec)
15
The amount of time the sys-
tem waits to until system ends
the call back.
15-22-04
Conditions
None
Feature Cross Reference
Refer to the Input Data table at the beginning of this section.
Issue 0.1
SL1000
Programming Manual
2-137
“30” in all SL100s.
Summary of Contents for SL1000
Page 1: ...SL1000 Programming Manual A50 031167 001 ISSUE 0 1 ...
Page 12: ......
Page 20: ......
Page 114: ...Program 14 Feature Cross Reference None Issue 0 1 SL1000 Program 14 Trunk Basic Setup 2 94 ...
Page 179: ...Program 20 Feature Cross Reference Class of Service Issue 0 1 SL1000 Programming Manual 2 159 ...
Page 377: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Programming Manual 2 357 ...
Page 386: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 366 ...
Page 396: ...Program 47 Feature Cross Reference None Issue 0 1 SL1000 Program 47 InMail 2 376 ...
Page 578: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 579: ...Issue 0 1 SL1000 Programming Manual MEMO ...
Page 580: ...SL1000 Programming Manual NEC Corporation Issue 0 1 ...