71
Setting Up Your Projector
2-5-2. Procedure for connecting the power cable (C1 connection)
Preparation:
Phillips-head screwdriver (No. 2), service key (projector accessory)
WARNING
• Before connecting the power cable, make sure that the AC power supply is disconnected. Otherwise a fire or electric shock
may occur.
• High leakage current flows. Do NOT connect the power supply before grounding connection.
1
Remove the plate inlet.
Remove the plate inlet by loosening the fixing screws (at four points).
In Europe, replace it with the supplied
φ
35 plate inlet. Use the fixing screws that were used before the replacement of the
plate inlet.
Plate Inlet
2
Pass the power cable through the cable hole of the plate.
If you use the supplied
φ
35 plate inlet, pass the power cable through a commercially available cable stopper and then
insert it into the cable hole.
Cable stopper
3
Remove the terminal cover of the power supply terminals.
Remove the terminal cover by pulling it upward.