140
Appendix
5-2. Error Code List
Please inquire your dealer/distributor about action to be taken for each error code.
Error Code
Error message
Description
4
GPSU Fail
Power supply is abnormal.
5
Light Unlit
The light source is not on.
12
EEPROM R Fail
E2PROM data read error.
13
Interlock
Interlock is activated.
15
EEPROM W Fail
E2PROM data write error.
120
DLP Ack Fail
Cinema circuit operation fail.
121
Lens Fail
Lens unit control error.
125
LPS Fail
Light Power Supply Switch is turned off.
Light Power Supply Voltage is abnormal.
139
ICP PowerOn Fail
Cinema circuit system startup fail.
141
DLP CommE Fail
Communication errror with cinema circuit.
165
GPI MACRO(n) Selection Invalid
Selection of preset button (n) through GPI is invalid because metadata is
enabled.
* This message would be shown on Log, not on LCD.
166
GPI Control Invalid
Projector control through GPI is invalid because projector is busy.
* This message would be shown on Log, not on LCD.
174
LU Not Found
Light unit install switch is open
177
Tamper Fail
Projector service door tamper switch is open.
178
Marriage Tamper Fail
Projector marriage tamper switch is open.
190
The Validity has expired.
The time limit for use of the projector has expired.
* In cases when the validity setting has been configured with the projector.
191
Different SN
There is a mismtach in the serial number of the main unit internally saved on
the projector.
192
Model Code Mismatch
There is a mismtach in the model code of the main unit internally saved on
the projector.
195
Exec LD CAL
Need to execute LD Calibration.
196
Exec SENS CAL
Need to execute Sensor Calibration.
271
IMB:SD Tamper Terminate
IMB service door tamper termination is executed.
* This message will not show on LCD.
305
Key Error
Projector private key error.
306
Certificate Error
Projector certificate error.
329
Sequence Data File Mismatch
Cinema circuit status error.
330
FMT DMD Data File Mismatch
Cinema circuit status error.
331
Flash Checksum Error - Sequence Data
Cinema circuit status error.
332
FMT Flash Checksum Error - DMD Data
Cinema circuit status error.
333
Satellite Hardware Mismatch
Cinema circuit status error.
335
Red Satellite Reports Reset
Cinema circuit status error.
336
Red Satellite Serial Link Error
Cinema circuit status error.
337
Red Satellite Firmware Configuration Error
Cinema circuit status error.
338
Red DAD1000 Bias Under Voltage Error
Cinema circuit status error.
339
Red DAD1000 Reset Under Voltage Error
Cinema circuit status error.
340
Red DAD1000 Offset Under Voltage Error
Cinema circuit status error.
341
Red DAD1000 Thermal Shutdown Error
Cinema circuit status error.
342
Green Satellite Reports Reset
Cinema circuit status error.
343
Green Satellite Serial Link Error
Cinema circuit status error.
344
Green Satellite Firmware Configuration Error
Cinema circuit status error.
345
Green DAD1000 Bias Under Voltage Error
Cinema circuit status error.
346
Green DAD1000 Reset Under Voltage Error
Cinema circuit status error.
Summary of Contents for NP-02HD
Page 9: ...9 Important Information Label Information Label A Label A Lamp Warning Label ...
Page 11: ...11 Important Information Label D Label E ...
Page 20: ...20 Wichtige Informationen Laseraustrittsmodule Aufkleber A Aufkleber A Lampenwarnschild ...
Page 22: ...22 Wichtige Informationen Aufkleber D Aufkleber E ...
Page 149: ......
Page 150: ... NEC Display Solutions Ltd 2019 Ver 1 0 06 19 ...