Message Waiting Lamp Setting - Attendant - CCIS
M-35 Message Waiting Lamp Setting - Attendant -
CCIS
General Description
This service feature allows the MESSAGE WAITING (MW) lamp on the D
term
or telephone set, equipped with MW
lamp accommodated in the Satellite Offices, to be controlled from the Attendant Console in the CCIS network.
Operating Procedure
To set MW Indication
1.
The Attendant in Node A presses an idle loop key.
2.
The Attendant enters the MW set code (maximum 3 digits); receives special dial tone.
3.
The Attendant dials Station (B), which is equipped with an MW lamp. The Attendant receives service set
tone. The MW lamp on Station B illuminates.
4.
The Attendant presses the RELEASE key and returns to an idle state.
To cancel MW Indication
1.
The Attendant presses an idle loop key, then enters the MW cancel code (maximum 3 digits); receives
special dial tone.
2.
The Attendant dials Station B, which is equipped with an MW lamp. The Attendant receives service set
tone. The MW lamp on Station B goes out.
3.
The Attendant presses the RELEASE key and returns to an idle state.
Service Conditions
1.
The MW lamp on a D
term
or single line telephone will be lit when this feature is activated.
2.
MW cannot be set when the Attendant is in a consultation condition with a station or trunk.
3.
An Attendant attempting to set MW to a station where MW has previously been set, will receive busy tone.
4.
In a MULTIPLE CONSOLE OPERATION [M-4], if MW is set by one ATTENDANT CONSOLE [A-3],
it can be cancelled by another.
ATT
[Node A]
[Node B]
STN (b)
CCIS
MW Lamp
SPDT
SP
DT
ATT
[Node A]
[Node B]
STN (b)
CCIS
MW Lamp is ON
SST
SS
T