ND-70348 (E)
CHAPTER 4
Page 707
Revision 3.0
AHSY
INDEX
(0 – 2047)
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
CONTENTS
DATA
0/1
BIT
102
b
0
LANG = 8
When an incoming call terminates to the Attendant
Console from a guest station of the language cate-
gory corresponding to each bit. The key to which
the call terminates:
0: GST1 Key
1: GST2 Key
Language data is assigned on each guest station ba-
sis as per the information from the PMS.
b
1
LANG = 9
b
2
LANG = 10
b
3
LANG = 11
b
4
LANG = 12
b
5
LANG = 13
b
6
LANG = 14
b
7
LANG = 15
103
Tenant Number of Paging Console
(2~63/255 = 02~FF Hex)
104
b
0
Miscellaneous Timer Counter (MTC) is to be as-
signed a value from 0 Hex to F Hex (0–15).
Paging Console Auto-
matic Recall Timer:
Timer Value Setting is
MTC
×
TC sec.
Note:
When this data
is 00 Hex, ROM
data is automati-
cally set to 3
min.
b
1
b
2
b
3
b
4
Timer Class(TC) is to be assigned one of the follow-
ing values:
b
5
b
6
b
7
Paging Console Automatic Recall Timer value
0/1 = Ineffective/Effective
b
6
b
5
b
4
b
6
b
5
b
4
0
0
0 = –
1
0
0 = 64 sec.
0
0
1 = 8 sec.
1
0
1 = –
0
1
0 = 16 sec.
1
1
0 = –
0
1
1 = 32 sec.
1
1
1 = –