ND-70348 (E)
CHAPTER 4
Page 652-2
Revision 5.0
ASIPL
ASIPL: Assignment of Station of IP Data for LDM
1. General
This command is used to assign and delete the IPELC terminal data of each IP Enabled Dterm station. It is also
used to read out the already assigned data and the data can be modified. The data is written in Local Data
Memory (LDM).
2. Precautions
1.
If the IP Enabled Dterm station is unavailable, error message “LP H/I Error (Error Code 0x0E03)” is
indicated.
2.
If the IP Enabled Dterm station is busy, error message “Line Busy” is indicated.
3.
If the IPELC card is not mounted, error message “IPELC data invalidity (Package is not mounted) (Error
Code 0x0A1F)” is indicated.
Note:
In case (1) (2) (3), the office data is to be assigned.
4.
It is required to initialize the IPELC card to validate the data assigned by this command.
5.
This command can be used since Release 10 software enhancement.
6.
Parameters “PRIn PAYLOAD_TYPE” and “PRIn PAYLOAD_SIZE” are available for IPELC Voice
Compress feature in IPX system.
3. Data Entry Instructions
Note 1:
JB_MIN data must not exceed the JB_MAX value.
PD
JB_MIN, JB_MAX (JB_MIN=JB_MAX)
PD
(JB_MAX) /2 (JB_MIN
JB_MAX)
Note 2:
Check the “DETAIL” box in case assignment for detail information is required. If “IPG=0” is entered, the
three parameters are all necessary and the “DETAIL” box might automatically be checked.
*Continued on the next page.
Enter the IPELC Group data.
Enter the Telephone Number of each IPELC
terminal (DtermIP station) within 16 digits.
USER
GROUP
NUMBER
(UGN)
IPELC
GROUP
DATA(IPG)
0-127
JITTER
BUFFER
MIN
(JB_MIN)
JITTER
BUFFER
MAX
(JB_MAX)
TELEPHONE NUMBER
(TELN)
MAX. 16 DIGITS [0-9, *, #]
TELN
IPG
PRIMARY
DELAY
(PD)
[1-30]
REMARKS
10ms
×
n (1 n 30)
Note 1, 2
JB_MIN/JB_MAX/PD