AUCDN: Assignment of UCD Control Data for NDM
1. General
This command is used to assign the miscellaneous data related to the Uniform Call Distribution (UCD) for Net-
fusing Service. The data assigned on this command is written in the Network Data Memory (NDM) of the Net-
work Control Node (NCN), updating the NDM at each Local Node (LN).
2. Precautions
1.
The UCD member station and UCD pilot (controlling station) station should be assigned by the ASHUN
command.
2.
This command can be specified using the following UCD related options:
(a) The maximum number of calls in UCD queuing
(b) The threshold of the UCD Call Waiting Lamp (which accommodated on a D
term
) start to flash
(c) Denial of the MCI call result text of the call terminated to the UCD group
3.
The following data should also be assigned for UCD - Call Waiting lamp flashing:
ASYD command, SYS1, INDEX 61, b5 = 1 (Call Waiting Display-UCD in Service)
AKYD command, FKY=47 (UCD Call Waiting Lamp)
4.
After the data assignment, the line circuit card which contains the UCD group stations must be initialized