CHAPTER 4
NDA-24299
Page 40
Revision 1.0
INSTALLATION
Key Setting on Circuit Cards
SW6C
1
ON
×
Fixed
2
ON
×
Fixed
3
ON
×
Fixed
4
ON
×
Fixed
5
ON
×
Fixed
6
ON
×
Fixed
7
ON
×
Fixed
8
ON
×
Fixed
SW58
1
ON
Equalizer Setting
OFF
2
ON
OFF
3
ON
OFF
4
ON
PAD Pattern Selection
Note:
When setting this key, refer to Digital
PAD Setting Table (
OFF
×
5
ON
×
OFF
6
ON
×
OFF
7
ON
Alarm Sending when this circuit card is in N-
OPE state.
OFF
×
8
ON
×
OFF
Table 4-4 Switch Setting Patterns for the DTI Card (Continued)
SWITCH NAME
SWITCH
NUMBER
SETTING
STANDARD
SETTING
MEANING
1
2
3
4
OFF
1
2
3
4
OFF
SW
58-1
SW
58-2
SW
58-3
DISTANCE
ON
ON
ON
0 - 131 ft.
(0 - 040 m)
ON
ON
OFF
131 - 262 ft.
(40 - 080 m)
ON
OFF
ON
262 - 393 ft.
(80 - 120 m)
ON
OFF
OFF
393 - 524 ft.
(120 - 160 m)
OFF
ON
ON
524 - 656 ft.
(160 - 200 m)
Other Combinations
Not Allowed
SW
58-4
SW
58-5
SW
58-6
PAD PATTERN
OFF
ON
ON
PAD Pattern 1
OFF
ON
OFF
PAD Pattern 2
ON
OFF
ON
A
→ µ
Loss
(Bothway)
ON
OFF
OFF
A
→ µ
Loss (Receive)
OFF
OFF
ON
µ→
A
Loss
(Bothway)
OFF
OFF
OFF
µ→
A
Loss (Receive)
Other Combinations
Not Allowed