Built-In AIT Auto-Loader Unit 27
4
Press the ENTER button.
The cleaning cartridge automatically starts cleaning the head. After cleaning, the cleaning
cartridge automatically returns to the magazine. The cleaning time depends on the place in
which the cleaning cartridge is set in the magazine (cartridge number) as shown below. (For
the cartridge number, refer to P. 11.)
Cartridge number in which the
Cleaning time
cleaning cartridge is set
1
Approx. 60 seconds
2
Approx. 75 seconds
3
Approx. 90 seconds
4
Approx. 105 seconds
5
Press the EJECT button.
The magazine is ejected.
6
Remove the cleaning cartridge from the magazine.
Hint
✎
Before using the AIT data cartridges, you should clean the read/write head using the cleaning
cartridge once a week. (The cleaning frequency varies depending on the operating environment
(generation of dust and dirt) and the operation frequency. When using the Built-In AIT Auto-
Loader Unit every day in a typical office, a weekly cleaning is recommended.)
Cleaning the driver
When the Built-In AIT Auto-Loader Unit looks contaminated, gently wipe it with soft cloth
moistened with water or detergent.
When the magazine looks contaminated, gently wipe it with soft dry cloth.
Important
Do not clean the Built-In AIT Auto-Loader Unit or magazine using chemicals such as benzene or
thinner (volatile chemicals), which may cause the unit to be deformed or discolored. For the same
reason, do not spray insecticide. If a chemical adheres to the driver or magazine surface,
immediately wipe it with soft cloth moistened with water.