2. System BIOS Setup
Express5800/T110g-E User’s Guide
123
Chapter 3 Setup
2.4
Cases that Require Setting Changes
Specify parameters according to the following table when your system matches "Description". The list of
SETUP parameters and factory settings are described in
Chapter 2 (1. Details of System BIOS)
in
"
Maintenance Guide
".
Category
Description
To be changed
Remark
Basic
Change date and time
Main
System Date
Main
System Time
Configurable on OS
On/Off NumLock on power ON
Boot
Bootup Numlock State
On/Off the function to display
the NEC logo during POST
Boot
Quite Boot
Disabled
By pressing <Esc> key, prevent
the display of the logo.
Optional
board
Install a
RAID controller
board
Advanced
PCI Configuration
PCI
Device Controller and Option ROM
Settings
PCI Slot n Option ROM
Enabled
n
is PCI slot number of the RAID
controller
Memory
Configure the memory after the
DIMM is added or exchanged.
Advanced
Memory Configuration
Memory Retest
Yes
After rebooting, the
Memory
Retest
setting changes to
No
automatically.
Boot
Change the boot order of
devices
Boot
Boot Option Priorities
Change the boot priority
Use remote power on feature
(from modem)
Advanced
Advanced Chipset
Configuration
Wake On Ring
Enabled
Use remote power on feature
(from RTC alarm)
Advanced
Advanced Chipset
Configuration
Wake On RTC Alarm
Enabled
Control from HW console
terminal
Advanced
Serial Port Configuration
Change respective setting.
Security
Set a password to restrict
operation of SETUP.
Security
Administrator Password
Security
User password
After a password is set, the
entry of password is displayed
when SETUP is launched.
Set a password to restrict
booting.
Security
Password on Boot
Enabled
You can select this parameter
after you set a password.
UPS
Powerlink
When the server is supplied
with power from UPS, always
turn on the power.
Server
Power Control Configuration
AC-LINK
Power On
If the server is turned off by
using POWER switch, leave it
OFF even when UPS supplies
power.
Server
Power Control Configuration
AC-LINK
Last State
Keep the power OFF even
when UPS supplies power.
Server
Power Control Configuration
AC-LINK
Stay off