263
Chapter 9
Clock Generator
Preliminary User’s Manual U15839EE1V0UM00
(2)
When released by RESET input
This operation is the same as normal reset operation. The Oscillator stabilization time must be
ensured by reset input.
Figure 9-11:
Sub Watch mode released by RESET input
Main Oscillation circuit stop
Sub-Watch mode setting
Main Oscillation circuit
System clock
Main OSC STOP state
RESET signal
Internal system
reset signal
Ensuring elapse of oscillation
stabilization time by RESET