NEC MultiSync

®

 90 Series

 

19” - 30” pro-level LCD displays ideal for medical applications

Professional Desktop

The NEC MultiSync 90 Series boasts our most advanced features to meet the demanding needs of the  
most discerning users. The ultimate in form and function make them ideal for many medical  
environments, including:

  • Soft-copy clinical viewing, including Picture Archiving and Communication System (PACS)
  • Computer tomography
  • Magnetic resonance imaging (MRI)
  • 3-D rendering

The MultiSync 90 Series’ active matrix (IPS, PVA) LCD modules boast the best  
possible color and grayscale accuracy and minimal (gamma) brightness tone shift  
at off angles. These features make these LCD displays more suitable for  
demanding, medical environment and multiple monitor applications.

ColorComp™

, an image uniformity compensation and correction system, aims to 

reduce any screen uniformity errors to almost unnoticeable levels. It works by  
applying a digital correction to each pixel on the screen to compensate for  
differences in color and luminance.

Automatic black level adjustment

 allows for better control of grayscale images. 

Video bandwidth can be adjusted to compensate for bad signals and gives you more  
flexibility in the number of signals you can view, while the auto adjust level can be 
customized to various settings for personal preferences when powering up a new system.

When enabled on the widescreen 24” LCD2490WUXi

2

, 26” LCD2690WUXi

2

 and 30” 

LCD3090WQXi, 

X-Light Pro™

, a built-in internal luminance and color sensor system, 

maintains calibration and consistent light output for the useful life of the display as well 
as corrects for short-term fluctuations. This allows the display to be used for image-critical 
applications within minutes of powering on. 

MultiSync 90 Series Highlights

(available on select models)

• Best in class with wide viewing angle, 
   active matrix LCD technology 
• ColorComp image uniformity 
   correction
• Calibration-capable to DICOM
• Selectable DICOM GSDF gamma
• High contrast ratio
• 12-bit lookup table (LUT)
• Automatic black level adjustment
• Complete OSD® lockout
• Pivot capability
• Backlight sensor

Achieve complete color and brightness 

uniformity. 

By nature, LCD panels contain 

uniformity errors, which are visible as slightly 

brighter or darker areas on the screen. To 

combat this inherent trait, each of these displays 

is individually characterized during production 

using a fully automated system that measures 

multiple points across the screen at different 

gray levels. These measurements are used to 

build a 3-D correction matrix stored inside the 

display. This data is used to compensate for 

the uniformity not only as a function of position 

on the screen but of gray level as well. In turn, 

this technology, called ColorComp, reduces the 

non-uniformity to virtually unnoticeable levels 

and applies a digital correction to each pixel on 

the screen to compensate for differences in color 

and luminance.

With ColorComp

Without ColorComp