background image

   

Express5800/R320c-E4, R320c-M4  User's Guide 

88 

NEC Express5800 Series 
Express5800/R320c-E4, R320c-M4 

Appendix 

1. Specifications 

Describes specifications of the server. 

 
 

Summary of Contents for EXP320P

Page 1: ... E4 Model Number N8800 173F EXP320P User s Guide Chapter 1 General Description Chapter 2 Preparations Chapter 3 Setup Chapter 4 Appendix 30 004 01 101 02 September 2013 Second Edition NEC Corporation 2013 Express5800 R320c M4 Model Number N8800 174F EXP320Q ...

Page 2: ...l options connection of peripheral devices and ideal location for this server Chapter 3 Setting Up Your Server System BIOS configurations and summary of EXPRESSBUILDER PDF Chapter 4 Appendix Specifications and other information Installation Guide Chapter 1 Installing OS Installation of OS and drivers and important information for installation PDF Chapter 2 Installing the Bundled Software Installat...

Page 3: ...upply and power cord use 15 Installation relocation storage and connection 16 Cleaning and working with internal devices 17 During operation 18 一般注意事項 19 機 架 20 電源及電源線注意事項 21 安裝 移動 保管及連接注意事項 22 清潔及操作內部設備時的注意事項 24 操作注意事項 25 Warning labels 26 External view 26 Handling precautions for proper operations 27 Chapter 1 General Description 30 1 Preface 31 2 Accessories 32 3 Standard Features 33 3 1 Featur...

Page 4: ...8 2 4 1 Connecting to a uninterruptible power supply UPS 70 Chapter 3 Setup 71 1 Power ON 72 1 1 POST Check 74 1 1 1 Flow of POST 74 1 1 2 POST Error Messages 76 1 1 3 Behavior at Occurrence of Error 76 2 SYSTEM BIOS SETUP 77 2 1 Overview 77 2 2 Starting and Exiting SETUP Utility 77 2 2 1 Starting SETUP 77 2 2 2 Exiting SETUP 77 2 3 Description on On Screen Items and Key Usage 78 2 4 Cases that Re...

Page 5: ...ctions could occur Note Indicates items that must be confirmed when handling the hardware or operating software Tips Indicates information that is helpful to keep in mind when using this server Optical disk drives This server is equipped with one of the following drives depending on the order at the time of purchase These drives are referred to as optical disk drives in this document DVD ROM drive...

Page 6: ...Server 2003 2 Windows Server 2003 Enterprise Windows 7 Professional 64 bit x64 Edition Windows 7 Windows 7 Professional 32 bit x86 Edition Windows Vista Business 64 bit x64 Edition Windows Vista Windows Vista Business 32 bit x86 Edition Windows XP Professional x64 Edition Windows XP Windows XP Professional Windows PE 3 Windows Preinstallation Environment 1 Includes 64 bit and 32 bit Editions unles...

Page 7: ...red trademarks of LSI Corporation Adobe the Adobe logo and Acrobat are trademarks of Adobe Systems Incorporated DLT and DLTtape are trademarks of Quantum Corporation of the United States PCI Express is a trademark of Peripheral Component Interconnect Special Interest Group Copyright 2010 VMware Inc All rights reserved This product is protected by U S and international copyright and intellectual pr...

Page 8: ...e harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada Class A Emission Compliance Statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformité à la réglementation d Industrie Canada Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada CE Australia and New Zealand Statem...

Page 9: ...udes Information and Communication Technology ICT equipment or electrical accessories such as cables or DVDs When disposing of used products you should comply with applicable legislation or agreements you may have The mark on the electrical and electronic products only applies to the current European Union Member States Outside the European Union If you wish to dispose of used electrical and elect...

Page 10: ...ors or omissions please contact your retailer 5 Regardless of these 4 items NEC Corporation does not take responsibility for effects resulting from operations 6 The sample values used in this document are not the actual values Keep this document nearby so that you may refer to it as necessary Latest editions This document was created based on the information available at the time of its creation T...

Page 11: ...g labels WARNING or CAUTION is used to indicate a degree of danger These terms are defined as follows WARNING Indicates there is a risk of death or serious personal injury CAUTION Indicates there is a risk of burns other personal injury or property damage Precautions and notices against hazards are presented with one of the following three symbols The individual symbols are defined as follows Atte...

Page 12: ...tric shock or fire may be caused Do not touch the server with wet hand Otherwise an electric shock may be caused Do not touch the component specified by this symbol Otherwise an electric shock or burn may be caused Do not use the server in the place where water or liquid may pour Otherwise an electric shock or fire may be caused Do not place the server near the fire Otherwise a fire may be caused ...

Page 13: ...tric shock Use a rack that conforms to the designated standard This server can be mounted onto a 19 inch rack that conforms to EIA standards Do not mount the server onto any rack that does not conform to EIA standards Doing so may cause a server malfunction personal injury or damage to peripheral devices For more information about racks that can be used with the server consult with your maintenanc...

Page 14: ...k components such as the door or rails When installing the door make sure that both upper and lower hinge pins are held in place Incomplete attachment may cause components to fall off as well as personal injury Do not extend any device from the rack that is not stabilized When extending a device from the rack make sure that the rack is stable by using a stabilizer or seismic reinforcement Otherwis...

Page 15: ... a single outlet by using extension cords The electric current exceeding the rated flow overheats the outlet which may cause a fire Insert the power plug into the outlet as far as it goes Heat generation resulting from a halfway inserted power plug imperfect contact may cause a fire Heat will also be generated if condensation is formed on dusty blades of the halfway inserted plug increasing the po...

Page 16: ...specified Do not install the server in the following places or any place other than specified in this User s Guide Failure to follow this instruction may cause a fire A dusty place A humid place such as near a boiler A place exposed to direct sunlight An unstable place Do not use the server in an environment where corrosive gas is present Do not install the server in a place subject to corrosive g...

Page 17: ...place any object on the cable Do not use the server with loose cable connections Do not use any damaged cable Cleaning and working with internal devices WARNING Do not disassemble repair or alter the server Never attempt to disassemble repair or alter the server on any occasion except as described in this document Failure to follow this warning may cause not only malfunction of the server but also...

Page 18: ...connect any devices There may be a risk of electric shock from lightning strike Keep animals away from the server Keep animals such as pets away from the server Pet hair or other waste enters the server which may cause a fire or electric shock Do not leave the optical disk drive tray open Dust may get in the server when the tray is open which may result in a malfunction In addition bumping the ope...

Page 19: ...人身事故及財產損失等後果 本公司概不負責 發生冒煙 異味 雜音時請勿使用 發生冒煙 異味 雜音等時 請立即關閉電源 並將電源插頭從插座上拔下 然後請與您的服務 代表聯繫 繼續使用會導致火災 伺服器內請勿插入鐵絲和金屬片 請勿將金屬片和鐵絲等異物插入通氣孔或軟碟機或光碟機的縫隙 有觸電的危險 請勿在未指定的場所使用本產品 請安裝伺服器於標準EIA 19吋的機架 請勿在不適當的場所安裝伺服器於機架 否則 可能造成伺服器及機架內的其他系統受到不良影響 且機架脫落可能導致火災或者人身傷 害 有關安裝環境和防震技術的詳細事項請參閱附帶的用戶手冊或與經銷商或維護服務公司聯 繫 請參照相關標準安裝伺服器於機架 請依照EIA標準安裝伺服器於機架內 請勿安裝伺服器於除了標準EIA 19吋以外的任何機架或不 適當的機架 否則可能引起伺服器操作不正確或人員傷害或周圍壞境設備的損害 請聯繫您伺服 器的機架服務代表...

Page 20: ...人以上的人來搬運或安裝機架 安裝伺服器時 請勿集中一個地方來承載所有的重量 在機架上加裝固定器來避免單一地方承載重量或同時安裝更多機架來分散承載重量 否則機架可能 倒下造成人員傷害 請勿一個人單獨安裝伺服器零件 請至少一人以上安裝包含如機架的門或托盤等零件 否則可能造成部份零件掉落損壞或人員傷害 請完全插入鏈栓 當安裝機架門時 請確認機架門上方及下方的鏈栓已完全插入機架 否則可能造成機架門掉落損壞 或人員傷害 請勿在機架不穩固時抽出設備 在抽出設備之前請確認機架式是穩固的 使用穩固器或者通過抗震技術固定 請勿從機架抽出超過一個以上的設備 同時抽出超過一個以上的設備可能導致機架傾倒 一次只能從機架抽出一個設備 請勿配線超過伺服器的電源功率 為了避免發熱 火災和設備損壞 請務必確保不要超過線路的額定負載 有關電力設備的安裝和電 線的更多資訊請聯繫電工或者當地的電力公司 ...

Page 21: ...過額定電流 會因過熱而導致火災的危險 請勿用拉的方式拔下電源線 要從伺服器拔下電源線時 請握住電源線的連接頭並直直的拔下 若僅拉住線的部份 會給予連 接頭過大壓力 導致線及連接頭的損壞 進而導致電擊傷害或火災 插入電源線到電源插頭時 請儘可能插入到底 若僅插入一半會因接觸不良而發熱造成火災 另插入一半的插頭部份 若附著灰塵或水滴等 也 會發熱而導致火災 請勿使用未經授權的電源線 請使用隨伺服器所檢附的電源線 若使用未經授權的電源線 當電流超過流動速率時可能引起火 災 此外 請注意下列事項以避免因電源線損壞導致電擊或火災 請勿伸長電源線 請勿夾住電源線 請勿彎折電源線 請勿讓電源線靠近化學藥品 請勿扭轉電源線 請勿在電源線上放置物品 請勿捆綁電源線 請勿對電源線進行改造 加工及修復 請勿用訂書針或其他東西等固定電源線 請勿使用任何已損壞的電源線 損壞的電源線要立即更換為相同規格的電源線 更換...

Page 22: ... 書機的CPU IO組件的重量是最大18Kg 有一個人運送的話腰疼痛的可能 請以2人以上好好地有底面運送裝置 還有 請別以安服務台bezel的狀態舉起 服務台bezel脫離掉下 成為傷的原因 請勿安裝或存放伺服器於未指定的場所 請勿將伺服器放置於以下或手冊內未指定的場所 否則有導致火災的危險 灰塵較多的場所 熱水器旁等濕氣較高的場所 陽光直射的場所 不平穩的場所 請勿在有腐蝕性氣體的環境中使用伺服器 請確認勿在有腐蝕性氣體 如二氧化硫 氫化硫 氮 氫 氨或臭氧等 的環境中使用或存放本 產品 請勿安裝於灰塵較多或含有腐蝕性物質如氯化鈉或硫磺 以及空氣中含有過量金屬碎末或傳導粒 子等的地方 否則會導致內部印刷版腐蝕或短路 引起火災的危險 請小心注意勿讓伺服器掉落 在安裝伺服器到機架時 請穩穩握住伺服器底部 此機架座並沒有停止器或機械鎖來避面伺服器 掉落 請遵守規定避免造成人員傷害 ...

Page 23: ...內風扇運轉造成故障或灰塵進入伺服器 內 造成電擊或火災 請勿讓手被滑軌或其他零件夾住 請務必小心您的手指可能在安裝伺服器到機架或從機架上卸載的時候 在滑軌及其他機械零件間 被夾住 或是被滑軌所劃傷 請勿在伺服器電源線連接插頭的狀態下 進行信號線的連接 在伺服器安裝 移動任何選配的內部設備或連接 拔除任何信號線之前 請確定關閉伺服器電源並 拔下電源線插頭 如果伺服器是關閉電源 但電源線插頭仍然插在電源插座上 在觸摸內部設備 信號線或連接頭時 可能引起電擊或因為短路引起火災 請勿使用未經授權的信號線 請使用NEC所提供的信號線 並在確認適當的設備及連接頭後再進行連接 使用未指定信號線或 連接錯誤等 會因為短路導致火災 此外 對於信號線的操作和連接 請遵守下列注意事項 請勿使用任何損壞的信號線接頭 請勿踩踏信號線 請勿在信號線上放置物品 請勿使用已鬆動的信號線來連接伺服器 請勿使用任何損壞的信號...

Page 24: ...或浸水均有可能發生爆炸 如果更 換不正確會有爆炸的危險 由於電池使用期限而導致伺服器無法正常運行時 請勿自行拆卸 更換或充電等 請與服務代表 聯繫 請依製造商說明書處理用過之電池 進入伺服器內部或連接週邊前 請先拔下電源插頭 清潔或安裝 移除伺服器內部的選購設備時 請確認關閉伺服器電源 並拔下電源插頭 即使已 關閉電源 但連接著電源線 接觸到任何內部設備也會有觸電的危險 請經常拔下電源插頭 用乾布擦拭灰塵和附著物 有灰塵或水滴等附著時會發熱 有導致火災的 危險 CAUTION 設備應避免高溫 伺服器關閉電源後 內置硬碟等內部設備仍然處於高溫狀態 請在充分冷卻之後再進行安裝 移 除任何零件 確認安裝完畢 配件板要確實安裝妥當 安裝不牢有可能引起接觸不良 造成冒煙和火災 請用保護蓋保護好未使用的連接頭 請用保護蓋保護好未使用的電源線連接頭 以防止短路或觸電 從內部設備上拔下電源插頭時 請用保護...

Page 25: ...s Guide 25 操作注意事項 CAUTION 遠離風扇 請保持您的手及頭髮遠離伺服器背後的冷風扇 否則您的手或頭髮有可能被夾住而造成傷害 避免在雷雨時接觸伺服器 當雷雨發生前請拔下電源插頭 若來不及拔下電源插頭 請勿觸摸伺服器的任何部份包含信 號線 以防止發生火災或觸電 寵物應遠離伺服器 否則可能導致火災和觸電 不要將光碟機托盤拉出放置 防止托盤中進入灰塵引起運轉錯誤 同時防止因碰撞等造成托盤損傷 非必要時 請勿將伺服器從機架拉出或移動 非必要時 請勿將伺服器從機架拉出或移動 否則可能造成伺服器無法正確操作 且伺服器 落下造成人員傷害 ...

Page 26: ...hazards This label is either attached or printed on the component to draw attention from users to potential hazards involved in handling the server Do not remove or black out this label and keep it clean If no label is attached or printed on the server or if there is a label coming off or stained contact your sales representative External view Front view Rear view ...

Page 27: ...t guarantee server operations temperature 10 to 35 C humidity 20 to 80 Check the system clock approximately once per month Use of a time server NTP server is recommended if high accuracy timing is required by the system Power suply Connect the provided power cord to a 100 VAC outlet Connect the dedicated power cord to a 200 VAC outlet Momentary voltage drop may occur due to lightning strike To pre...

Page 28: ... To protect important stored data and property make sure to wait for a sufficient period to use the server and components in the operating environment Reference Time effective at avoiding condensation in winter more than 10 C differences between the room temperature and atmospheric temperature Disk devices Approximately 2 to 3 hours Tape media Approximately 1 day For optional devices we recommend ...

Page 29: ...creen from reflecting bright lights and to make the display contents easy to see Working without adjusting the display to a comfortable angle makes it difficult for you to maintain a proper posture and you will get tired easily Adjust the viewing angle before use Adjust the brightness and contrast of the display Display screens have functions to control brightness and contrast The most suitable br...

Page 30: ...ntroduces the features of this server and the name of each part 1 Preface 2 Accessories Verify the condition of your server s accessories 3 Standard Features This section describes the server s features and the server management 4 Names and Functions of Components This section describes the name of each part contained in this server ...

Page 31: ...trouble its dual configuration will allow the system to instantaneously isolate the failed parts to assure non stop running operation will be moved smoothly from one module to the other minimizing damage to it You can use this Express5800 ft series in a mission critical system where high availability is required By the use of Windows VMware operating system it also provides outstanding openness fo...

Page 32: ...ts are stored in EXPRESSBUILDER Adobe Reader is required to read the documents so make sure you have it installed in your PC Make sure you have all accessories and inspect them If an accessory is missing or damaged contact your sales representative Important The chassis serial number plate and maintenance label is located on the server If the serial number does not match the number on the warranty...

Page 33: ...bps 10Mbps supported 10GBASE T 1000BASE T 100BASE TX 2 ports interface 10Gbps 1Gbps 100Mbps supported Express5800 R320c M4 only High reliability Memory monitoring feature error correction error detection Bus parity error detection Temperature detection Error detection Internal fan monitoring feature Internal voltage monitoring feature BIOS password feature The security lock that comes with Front B...

Page 34: ...nt 1 port rear 3 ports Onboard LAN Express5800 R320c E4 2 ports Express5800 R320c M4 4 ports Management LAN port 1 port Ready to use No cable connection is required to install a hard disk drive hot swap supported Many built in Features El Torito Bootable CD ROM no emulation mode format supported Software power off Remote power on feature AC Link feature Power switch mask Baseboard Management Contr...

Page 35: ...server data on an independent storage system These features eliminate server downtime that is usually caused by network disconnection or trouble with the I O controller network adapter or disk drive and support operation of the network and server applications continuously Express5800 ft series detects status changes errors the Windows VMware Log of these events If you use an alarm notification too...

Page 36: ...ration Express5800 ft series constantly monitors events If trouble occurs on Express5800 ft series server module it will transparently use a redundant module of the failed module This feature maintains data and user access without losing application service Automatic reconfiguration When the failed module restarts after the trouble is corrected Express5800 ft series will perform reconfiguration au...

Page 37: ...red and all processors installed on this server are shown How CPU modules appear on Task Manager Logical CPUs are displayed as many as there are System with one CPU Quad Core System with two CPUs Quad Core The above are screens when Express5800 R320c E4 is used For Express5800 R320c M4 up to 8 logical CPUs are displayed in the one CPU configuration and up to 16 logical CPUs are displayed in the tw...

Page 38: ...deo Monitors temperatures fans voltage power supply and others Temperature Monitors the temperature inside of the chassis Fan Monitors the fans Voltage Monitors the voltage inside of the chassis Power supply Monitors the power supply unit System environment Cover Door X Monitors Chassis Intrusion open close state of chassis cover or door Software Shows service driver and OS information Network Sho...

Page 39: ... Version Management for Windows Use of NEC ESMPRO Manager and ExpressUpdate Agent allows you to manage versions of firmware and software as well as update them by applying update packages This feature automatically updates modules without stopping the system just by specifying the updating packages from NEC ESMPRO Manager ...

Page 40: ...s fails the LED goes on amber Details can be confirmed by checking 14 EXPRESSSCOPE The LED goes on amber when the failed CPU IO module cannot be identified 3 System FT LED This LED displays the device status The LED lights in green when operating under duplex condition The LED goes off if it is not in duplex condition The LED blinks in green while executing Active Upgrade 4 System ID LED This LED ...

Page 41: ...D goes on amber Details can be confirmed by checking 14 EXPRESSSCOPE The LED goes on amber when the failed CPU IO module cannot be identified 9 System FT LED This LED displays the device status The LED lights in green when operating under duplex condition The LED goes off if it is not in duplex condition The LED blinks in green while executing Active Upgrade 10 System ID LED This LED is used to id...

Page 42: ...4 Names and Functions of Components Express5800 R320c E4 R320c M4 User s Guide 42 Chapter 1 General Description 4 3 Rear View R320c E4 model R320c M4 model ...

Page 43: ... 2 2 SPEED LED 5 LAN connector Network connector supporting 1000BASE T 100BASE TX 10BASE T 5 1 LAN1 5 1 1 LINK ACT LED 5 1 2 SPEED LED 5 2 LAN2 5 2 1 LINK ACT LED 5 2 2 SPEED LED 6 Power unit Standard power supply unit 6 1 Stopper Lever for the CPU IO module not to be disconnected with the power cord connected Ensure that the bar is not unset to remove CPU IO module 6 2 Ejector 6 3 Power Unit LED ...

Page 44: ...ponents Express5800 R320c E4 R320c M4 User s Guide 44 Chapter 1 General Description 4 4 External View 1 Front bezel The cover to protect devices in the front 2 LEDs For more information refer to the description Chapter 1 4 8 LEDs ...

Page 45: ...ter 1 General Description 4 5 Optical Disk Drive 1 Status LED The LED lights while accessing the loaded optical disk 2 Tray eject button The button to eject the tray 3 Manual release If the tray eject button fails to eject tray insert a metal pin into this hole to forcibly eject the tray ...

Page 46: ...ames and Functions of Components Express5800 R320c E4 R320c M4 User s Guide 46 Chapter 1 General Description 4 6 CPU IO Module R320c E4 with top cover removed R320c M4 with top cover removed PCI riser card ...

Page 47: ... User s Guide 47 Chapter 1 General Description The figure below shows internal view of CPU IO module when duct is removed 1 HDD BP Backplane 2 Cooling fan 3 Processor CPU Mounted below the heat sink 4 DIMM Option 5 CPU IO board 6 Riser card R320c M4 only 7 Power unit ...

Page 48: ...om top 3 2 DIMM16 to DIMM13 from top Available only when CPU 2 is installed 4 Lithium battery 5 HDD BP connector 6 CMOS Clear jumper Refer to Chapter 1 10 3 Clearing BIOS Settings CMOS Memory in Maintenance Guide 7 Password Clear jumper Refer to Chapter 1 10 3 Clearing BIOS Settings CMOS Memory in Maintenance Guide 8 Connector for PCIe card 8 1 PCI slot 1 8 2 PCI slot 2 9 1G LAN connector 9 1 LAN1...

Page 49: ...r Messages by LED Indication in Maintenance Guide System POWER LED System FAULT LED System FT LED System ID LED With front bezel installed System POWER LED System FAULT LED System FT LED System ID LED System POWER LED Disk ACCESS LED EXPRESSSCOPE Optical disk STATUS LED Front View LINK ACT LED SPEED LED GLAN connector Power unit LED Module ID LED Management LAN port 10GLAN connector R320c M4 model...

Page 50: ...cribes preparations for using this server 1 Installing Internal Optional Devices Describes how to install or remove optional devices You can skip this section if you did not purchase any optional devices 2 Installation and Connection You must place the server in a suitable location and connect some cables following this section ...

Page 51: ...2 4 Installing Optional Devices in Maintenance Guide for how to install internal option devices for VMware You do not need to provide any settings for software If you did not purchase any optional device requiring installation you may skip this section Important Use only the devices and cables specified by NEC You will be charged to repair damages malfunctions and failures caused by the use of any...

Page 52: ...f the server handle the optical disk drive or remove install a hard disk drive or CPU IO module remove the front bezel Removal 1 Insert the provided security key bezel lock key into the key slot and push lightly Turn the key to the left to unlock 2 Hold the right edge of the front bezel and pull it forward 3 Slide the front bezel to take the tab off the frame and remove the front bezel Installatio...

Page 53: ... wire to a gas pipe CAUTION Be sure to observe the following precautions to use the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Do not carry or install the server only by a single person Remove the CPU IO module from the server before moving the server Do not install the server so that th...

Page 54: ...the air or dust includes components accelerating corrosion ex sulfur sodium chloride or conductive metals Place where chemicals may be accidentally sprayed over Place where a carpet not subject to anti static process is laid Place where some objects may be fallen on the rack Place near a device generating intense magnetic field such as TVs radios broadcast communication antennas power transmission...

Page 55: ...recautions in Precautions for Use Do not drop the server 4U chassis weighs about 10 kgs At least two persons are required to install it CPU IO module weighs about 18 kgs At least two persons are required to install it Do not leave the CPU IO module of the server being pulled out Do not install the CPU IO module with its cover removed Do not get your fingers caught Important Temperature increases a...

Page 56: ...es are not included Use the core nuts provided with the rack Checking the place to install Decide the place height to install Next to the square hole of the rack an imprinted mark is placed for 1U This is the unit to show the height of the rack This device is as high as 4U about 176 mm so install it between the imprinted marks that indicate the height of 4U Note To keep balance install it as low a...

Page 57: ...side of the rack Install the brackets with its flat side facing inside Place them with the panhead screws with washers that come with the device symmetrically total 4 Fasten the screws tentatively not tightly 3 Fix the core nuts to the front side of the rack Attach them symmetrically total 4 core nuts 4U 装置上面 装置底面 Flat washer ワッシャ付き 鍋ネジ Panhead screws with washers Bottom of device 4U top of device...

Page 58: ...p to a hole by a flat blade screwdriver Note Make sure that the core nuts on left and right sides are level 4 Remove two CPU IO modules from the chassis 5 Loosen the screw and remove the DVD drive unit from the chassis 6 Loosen the screw and remove the system backplane from the chassis 7 Insert the chassis from the front side of the rack システムバックプレーン ネジ System backplane Screws ラックの外側 ラックの内側 Outside...

Page 59: ... and back sides total 8 from the rear 9 Fasten tightly the pan head screws attached to the device to each 2 places right and left total 4 from the front 10 Fasten tightly the 4 pan head screws on the back side and the 8 flat screws on the side panels which you fastened tentatively Panhead screw with washer Panhead screw on side panel Panhead screw on rear Flat screws Flat screws Panhead screw on s...

Page 60: ...re it with screws 12 Mount the DVD drive unit and secure it with screws 13 Mount the CPU IO module 0 Tips Mount the module while lowering the lock so the module stacks on the way 14 Raise the levers on the left and right sides 15 Fasten the levers on the left and right sides with screws 16 Mount the CPU IO module 1 in the same way Lock ...

Page 61: ...e steps below and unmount the device from the rack 1 Check that the server is powered off and remove all the power cords and interface cables from the server 2 Remove the front bezel 3 Loosen the screws on the left and right sides of the front panel of the CPU IO module and release the lock by pulling the ejector toward you 4 Pull out the CPU IO module carefully from the rack Important When you pu...

Page 62: ... connect the ground wire to a gas pipe CAUTION Be sure to observe the following precautions to use the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Do not carry or install the server only by a single person Remove the CPU IO module from the server before moving the server Do not install th...

Page 63: ...ayed over Place whose floor is covered with non antistatic carpet Place that may be subject to falling objects Place that is close to some equipment that generates intense magnetic field e g TV set radio broadcasting communications antenna power transmission wire and electromagnetic crane If unavoidable contact your sales agent to request proper shield construction Place where the power cord of th...

Page 64: ... least two persons are required to install it CPU IO module weighs about 18 kgs At least two persons are required to install it Do not leave the CPU IO module of the server being pulled out Do not install the CPU IO module with its cover removed Do not get your fingers caught 1 Open the front door of the tower conversion kit Tips If the door is locked use the provided security key to unlock 2 Conf...

Page 65: ...O modules from the chassis 6 Remove the DVD drive unit from the chassis 7 Remove the rack mount bracket handle from the front of chassis You cannot close the door with the handle being mounted Keep the removed handle and screws carefully They are needed when installing the server in rack 8 Insert the chassis from the front side of the tower conversion kit Note Push the chassis to the end of tower ...

Page 66: ... Fix each 2 places top and bottom on the front side total 4 with 4 pan head screws attached to the device 10 Fix the chassis to the tower conversion kit with 4 flat screws 11 Mount AC rock bracket and secure it with a screw Tower conversion kit on the rear top Tower conversion kit on the rear bottom ...

Page 67: ...is and secure it with screw 13 Slowly and carefully insert the CPU IO module 0 into the chassis Tips Keep pressing down the lock lever to keep it unlocked when the insertion is locked 14 Close the levers on the top and the bottom and secure the CPU IO module with screws 15 Install the CPU IO module 1 to the chassis with the same procedures ...

Page 68: ...ause death or serious injury For details refer to Safety precautions in Precautions for Use Do not hold the power plug with wet hands Do not connect the ground wire to a gas pipe CAUTION Be sure to observe the following precautions to use the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Us...

Page 69: ...ting peripheral devices with the exception of peripherals with USB interface Connecting a powered peripheral device to the powered server will cause malfunctions and failures In the case of standard configuration you need to complete setup of the operating system before installing external file backup device The serial port connectors are reserved for maintenance When the device is not Plug and Pl...

Page 70: ...to a UPS the BIOS settings may need to be changed in order to link the server with the power supply from the UPS To change the settings select Server and then AC LINK in the BIOS setup utility and change the displayed parameters Select Power On to perform automatic operations by using the UPS For details refer to Chapter 3 1 System BIOS in Maintenance Guide Option slot Overload protection reset bu...

Page 71: ...etup You can customize the BIOS settings by following the instructions in this section 3 EXPRESSSCOPE Engine 3 EXPRESSSCOPE Engine 3 provides useful features through the Baseboard Management Controller BMC 4 EXPRESSBUILDER EXPRESSBUILDER helps you to install Windows and maintain the server 5 Installing Software Components You can install Windows and bundled software 6 Power OFF Power off the serve...

Page 72: ...s 0 and 1 start blinking green If you power off the server wait at least 30 seconds before turning it on again 1 Power on the display unit and other peripheral devices connected to the server Note If the power code is connected to a power controller like a UPS ensure that it is powered on 2 Remove the front bezel 3 Lift up the acrylic cover in front of the power switch and press the POWER switch o...

Page 73: ...e NEC logo will appear on the screen Important Do not connect or disconnect USB device while POST is running Do not power off the server while POST is running While the NEC logo is displayed on the screen Express5800 ft series executes a power on self test POST to check hardware For details refer to Chapter 3 1 1 POST Check ...

Page 74: ...omes operable after the logo appears 2 If Enabled is specified for Password On Boot in Security menu of SETUP you will be prompted to enter password after the logo is displayed If you enter the incorrect password three times consecutively POST aborts You can no longer proceed In this case power off the server and power it on Important Do not set a password before OS is installed 3 If Esc key is pr...

Page 75: ...f you wait for a few seconds POST will go on automatically Example Tips You need to start SAS BIOS Setup Utility only when you want change configuration of built in SAS controller To launch utility press Ctrl C while the message appears on screen When utility is completed the server will reboot itself automatically and perform POST For details on the utility refer to Chapter 3 3 SAS Configuration ...

Page 76: ... that was secondary before reboot is determined as primary module and POST or OS runs on that module switching of boot pair If POST does not complete normally on both CPU IO modules the server will stop with the state of DC OFF or POST halts with an error message displayed The following devices are connected to the primary CPU IO module When one CPU IO module is disconnected because of a failure t...

Page 77: ... Run POST following Chapter 3 1 1 1 Flow of POST After a while the following message will be displayed on the lower left of the screen The on screen message depends on your system environment Press F2 SETUP F4 ROM Utility F12 Network If you press F2 key at this time SETUP runs and displays Main menu upon completion of POST You can also press F2 key to display Main menu while option ROM is expanded...

Page 78: ...cannot use this key when a menu which has on the left is selected Enter key Press this key to confirm the selected parameter Esc key Pressing this key cancels pop up dialog or takes you to the previous screen on submenu screen If you keep pressing this key on Main menu the following window is displayed If you select Yes the SETUP closes without saving the changed parameters Quit without saving Yes...

Page 79: ...s are restored Load Previous Values Yes No F3 key If you press this key the following window appears If you select Yes restore the parameters of the currently selected item to the default setting This might be different from the parameters configured before shipment Load Setup Defaults Yes No F4 key If you press this key the following window appears If you select Yes the parameter you configured i...

Page 80: ...anced PCI Configuration PCI Slot X Option ROM Enabled X is PCI slot number of the option board Change the boot order of devices Boot Boot Option Priorities Change the boot priority When you use EXPRESSBUILDER set CD DVD to the highest priority Boot Use remote wake up function via LAN Advanced Advanced Chipset Control Wake On LAN PME Enabled Set a password Security Administrator Password Enter a pa...

Page 81: ...correct password 3 times operation stops You cannot operate further Turn off the power Saving changes If you finish configuration select Save Exit and then Save Changes and Exit to save changes and exit If you wish to exit without saving the changed parameters select Save Exit and then Discard Changes and Exit Or if you wish to restore the setting to default values select Save Exit and then Load S...

Page 82: ...ature and voltage of the server If you have the management LAN port connected to the network you can remotely perform the following over a web browser or SSH client Manage the server Remotely control the keyboard video and mouse KVM Remotely access a CD DVD floppy disk ISO image USB memory To actualize these functions virtual USB mass storage Remote FD Remote CD DVD Remote USB Memory or Virtual Fl...

Page 83: ...he following message appears on the lower left of the screen Press F2 SETUP F4 ROM Utility F12 Network 2 If you press the F4 key at this time Off line TOOL starts upon completion of POST You can also press the F4 key while the NEC logo is being displayed to open the Off line TOOL MENU screen 3 The keyboard selection screen appears Select your keyboard type After that the Off line TOOL MENU screen ...

Page 84: ...following screen is displayed On this screen enable or disable DHCP or specify IP Address Subnet Mask 6 Connect the LAN cable to the management LAN connector in order to connect to the network It will be available for use if you access EXPRESSSCOPE Engine 3 via Web browser from management PC according to the setting ...

Page 85: ...Diagnoses your server system To use this feature select Tool menu in the menu after boot Storage of documents Stores various documents including User s Guide Installation Guide and Maintenance Guide 4 2 Using EXPRESSBUILDER Use EXPRESSBUILDER provided with the server to install operating system or diagnose your system Start EXPRESSBUILDER in the following procedure Set the DVD to the optical disk ...

Page 86: ...s Express5800 R320c E4 R320c M4 User s Guide 86 Chapter 3 Setup 5 Installing Software Components Continue to install software components such as OS Refer to the instructions below Installation Guide Windows Installation Guide VMware ...

Page 87: ...UPS see manuals provided with the UPS or the application that controls the UPS 1 Shut down the OS 2 The server automatically turns off after the OS shuts down The Module POWER LED on each CPU IO module will be blinking when AC power is supplied 3 Power off all peripheral devices Tips Hibernate function of Windows Server cannot be used Do not set Hibernate at Windows shutdown ...

Page 88: ...Express5800 R320c E4 R320c M4 User s Guide 88 NEC Express5800 Series Express5800 R320c E4 R320c M4 Appendix 1 Specifications Describes specifications of the server ...

Page 89: ...ane x8 socket Low profile Chip Video RAM Management controller chip 32 MB Graphics Graphic display resolution 16 770 000 colors 640 480 800 600 1 024 768 65536 colors 1 280 1 024 Interface 4xUSB 2 0 1x Front 3x Rear 1x Analog RGB Mini D sub 15 pin 1x Rear 2x1000BASE T LAN connector 1000 100 10BASE T RJ45 2x Rear 1x Management LAN connector 100 10BASE T RJ45 1x Rear 4xUSB 2 0 1x Front 3x Rear 1x An...

Reviews: