Issue 1.0
7-22
Handset Feature Settings
3.5.6
Administrator Site Survey Settings - Sync Display Mode
To start Sync Display mode:
Press the
Sync
key.
Scan complete; information displayed:
The results of the scan are displayed in the
LCD.
Band
- the carrier band for the handset.
Condition
- Good / Fair / Poor
Clear Slot
- number of clear slots (total
number of slots is 12).
Number of Base
- the number of the base
station.
Keys available when requesting a site
survey include:
Scan
key - restarts scanning for clear slots
and number of base stations.
Sync
key - begins Sync Display mode.
Start Sync Display mode:
When the
Sync
key is pressed, the Sync
Display mode displays the following
information:
Ch
- the current channel number.
Slot
- the current slot number.
RSSI
- the current RSSI (Receive Signal
Strength Indication) value.
BER
- the Bit Error Rate.
RFPI
- the RFPI (Radio Fixed Part Identity)
or base station ID.
H/O
- Hand Over Enable/Disable
Lost
- Lost counter
L
- status (locked or unlocked)