DS2000 System Load Factor Calculations
To check your DS2000 system configuration:
1.
Indicate the quantity for each item installed in the
Qty
column.
2.
For each item, multiply the
Qty
times the
Load Factor
and enter the value in the
Total Load
column.
3.
Add all the values in the
Total Load
column and enter the value in
Item 1
.
4.
Determine the System Load Factor capacity of the power supplies installed in your system
and enter the total in
Item
2
.
A 4-Slot Cabinet can have only 1 power supply. An 8-Slot Cabinet can have up to 3
power supplies. You cannot have more than two 16DSTU PCBs per power supply, regard-
less of System Load Factor calculations.
5.
Compare the entry in
Item
2
to your entry in
Item
1
. Item 1 must always be equal to or less
than the entry in Item 2.
Do not operate your system if the System Load Factor total (Item 1)
exceeds the allowable value (Item 2).
DS2000 System Load Factor Calculations
Item
Load Factor
Qty
Total Load
Each Digital Telephone and Dig-
ital Door Box
1
4ASTU PCB
8
8ASTU PCB
12
110-Button DSS Console
2
24-Button DSS Console
1
Total DSS Consoles installed cannot exceed 4.
2-OPX Module
4
Item 1:
Total load for this configuration:
Item 2:
If you have one power supply installed, enter 48.
If you have two power supplies installed, enter 80.
If you have three power supplies installed, enter 112.
(2 16DSTU PCBs maximum per power supply)
Note: An 8-Slot Cabinet can have up to 3 power supplies. You cannot have more than
two 16DSTU PCBs per power supply, regardless of System Load Factor calculations.