![NEC DLP Cinema NC3200S Installation Manual Download Page 173](http://html.mh-extra.com/html/nec/dlp-cinema-nc3200s/dlp-cinema-nc3200s_installation-manual_250231173.webp)
5. Steps to upgrade to 4K
173
6.2
Error Code List
Please inquire your dealer/distributor about action to be taken for each error code.
Error code
Error message
Description
1
Lamp Door Open
Lamp door (cover) is open.
2
Lamp
OverTemp
Temperature (lamp temperature) is
abnormal.
4
GPSU(12V) Fail
Power supply is abnormal.
5
Lamp Unlit
Lamp doesn’t light up.
6
House OverTime
Lamp house cumulative time is over.
8
LPSU
OverTemp
Temperature (lamp power inside
temperature) is abnormal.
12
E2PROM R Fail
E2PROM data read error is detected.
13
Interlock Fail
Interlock is activated.
15
E2PROM W Fail
E2PROM data write error is detected.
17
Pump Stop
Stopped for pump error.
120
DLP Ack Fail
ICP failed operation. It could be caused by
configuration files lost, disk space issue, or
DISKCHIP corruption issue.
123
Bulb OverTime
Lamp bulb cumulative time is over.
125
LPSU Fail
Lamp power supply is abnormal.
128
OutRange
Adjusting lamp output value has set out of
range.
129
Down Lamp Power
Down lamp power to decrease set inside
temperature.
130
MMS Comm Fail
MMS communication error is detected.
131
MMS Fan Stop
MMS fan has stopped.
132
MMS Fail
MMS internal error.
133
MM Reset
Executed to reset MMS.
140
DLP CommR Fail
No communication with the ICP board.
(Communication I/F is RS-232C)
141
DLP CommE Fail
No communication with the ICP board and
DCC.
(Communication I/F is Ethernet)
145
SensorFail Outside Air
Sensor (Outside Air) read error.
146
SensorFail LPSU Intake
Sensor (LPSU Intake) read error.
147
SensorFail Exhaust
Sensor (Exhaust) read error.
148
SensorFail DMD-B
Sensor (DMD-B) read error.
150
Fan0 Stop
Fan0 has stopped.
151
Fan1 Stop
Fan1 has stopped.
152
Fan2 Stop
Fan2 has stopped.
153
Fan3 Stop
Fan3 has stopped.
154
Fan4 Stop
Fan4 has stopped.
155
Fan5 Stop
Fan5 has stopped.
156
Fan6 Stop
Fan6 has stopped.
157
Fan7 Stop
Fan7 has stopped. (NC3200 Series)
158
Fan8 Stop
Fan8 has stopped. (NC3200 Series)
159
Fan9 Stop
Fan9 has stopped. (NC3200 Series)
160
GPSU Fan Stop
Fan has stopped.
162
Lamp Fan0 Stop
Lamp Fan0 has stopped.