1800 - Extension Options
1801 - Extension Port Description
IntraMail System Guide
Chapter 3: Programming
◆
201
3
1801 Program Entry
1801 - Extension Port Description
(Entry Range) [Default Setting]
ICM
+
#*#*
+ Password (372000) +
HOLD
+
1801
+
HOLD
.
EXTENSION #
(Any valid extension number) [300]
PT TYP
(The following circuit type options are available:)
00=uninstalled
01=22-Button Standard
02=22-Button Display
06=34-Button Display
09=34-Button Super Display
10=Door Box
15=Analog Station
21=2-OPX Module)
[By default, digital station ports automatically detect the type of connected device
when the keyset, 2-OPX Module or Digital Door Box is plugged in. If no device is
connected, the default setting is circuit type 02.]
•
To scroll through the available types:
- Press
ICM
(the
ICM
key
fl
ashes)
- Press
VOL
▲
or
VO
L
▼
to scroll through the entries.
- Press
HOLD
to accept the displayed entry.
EXT
(Extension number - view only)
NAME
(Name) [No names entered]
When entering names, see the
DOOR CHIME
(For Door Boxes only: 0=Normal Ring Group ringing, 1=Low pitch chime pattern,
2=Mid range pitch chime pattern, 3=High pitch chime pattern) [0]
RELAY OWNER
(For Door Boxes only:)
(DS1000: 0 = Relay not assigned, 1=Relay assigned to DOOR1, 2=Relay
assigned to DOOR2) [0]
(DS2000: 0=CPU relay not assigned to Door Box, =CPRU Relay assigned to
Door Box) [0]
DSS TYPE
(0=Uninstalled, 1=24-Button, 2=110 Button) [0]
DSS BLOCK NUM
(1-4) [1]
CLASS OF SERVICE
(1-15) [Extension 300=1, All others=2]
STA TOLL LVL DAY
(1-7, 0=No restriction) [0]
STA TOLL LVL NITE
(1-7, 0=No restriction) [0]
ACCESS LVL
(0-5) [Extension 300=5, All others=3]
OVRFLW EXT
(Any valid extension number) [300]
DID OVRFLW B-R-D
(0=No over
fl
ow, 1=Busy/DND Over
fl
ow, 2=Ring No Answer Over
fl
ow, 3=Busy/
DND and Ring No Answer Over
fl
ow) [0]
Press this:
To do this:
HOLD
Enter (accept) data you entered, advance to the next prompt without changing your entry, or nav-
igate to the next prompt level.
CONF
Cancel your entry and back up to the previous prompt level.
VOL
▲
or Vol
▼
Scroll to the next prompt on the same prompt level.
LND
Erase the entry to the left of the cursor.
CHECK
Restore the previous entry.
CLEAR
Clear the entry from the display (unless otherwise noted).