4-40
8.
Press
Esc
to return to the TOP menu and exit MegaRAID Configuration Utility.
NOTES:
Select "Objects"
→
"Physical Drive"
→
"Fail Drive" to cancel the hot spare setting.
When there are 2 or more hard disks (of the same capacity) set as hot spare, rebuilding
is performed in order starting from the one with the smaller CH number/ID number.
Checking consistency
Start MegaRAID Configuration Utility
Perform consistency check
Exit MegaRAID Configuration Utility
Procedure
1.
Start MegaRAID Configuration Utility.
2.
Select "Check Consistency" from the TOP menu.
3.
The "Logical Drives" screen appears. To run the consistency check, move the cursor onto the logical drive and
press
Space
to select it. Pressing
F2
selects all logical drives.
4.
When logical drive selection is completed, press
F10
to start consistency check.
A confirmation screen for execution appears. Select "Yes" to start consistency check.
5.
When the meter display in the "Check Consistency Progress" screen indicates 100%, the consistency check is
completed.
6.
Press
Esc
to return to the TOP menu and exit MegaRAID Configuration Utility.
IMPORTANT:
Be sure to perform consistency check after creating configuration.
Summary of Contents for 140He
Page 1: ...User s Guide Express5800 140He...
Page 2: ......
Page 4: ...This page is intentionally left blank...
Page 60: ...2 32 This page is intentionally left blank...
Page 170: ...5 20 This page is intentionally left blank...
Page 328: ...B 6 This page is intentionally left blank...
Page 342: ...D 10 This page is intentionally left blank...
Page 354: ...E 12 This page is left intentionally blank...
Page 359: ......
Page 360: ......