4-34
IMPORTANT:
Notice status display of "Disable (Enable) BIOS".
Selected Enable : Indicate "Disable BIOS"
Selected Disable: Indicate "Enable BIOS"
When "Factory Default" is executed, the setting values are changed.
Set each parameter after executing "Factory Default."
Some versions of MegaRAID Configuration Utility change the "Factory Default"
setting value.
Check each parameter setting after executing "Factory Default."
The server must be restart after executing "Factory Default."
Operating Procedures for Configuration Utility
Creating/adding configuration
Start MegaRAID Configuration Utility
Set new configuration information (pack/logical drive settings)
Check the logical drive settings
Initialize logical drive
Exit MegaRAID Configuration Utility
Procedures
1.
Start MegaRAID Configuration Utility to check each setting parameter.
2.
Select "Configure"
→
"New Configuration" from the TOP menu (Management Menu).
Select "View/add Configuration" to add configuration.
IMPORTANT:
When a new configuration is created by selecting "New Configuration," the existing
configuration information is cleared. To add configuration information to that existing,
select "View/add Configuration."
"Easy Configuration" cannot set logical drive capacity or create SPANNING OF RAID1.
Select "New Configuration" or "View/add Configuration" to execute these.
3.
When a confirmation message (Proceed?) is displayed, select "Yes."
Summary of Contents for 140He
Page 1: ...User s Guide Express5800 140He...
Page 2: ......
Page 4: ...This page is intentionally left blank...
Page 60: ...2 32 This page is intentionally left blank...
Page 170: ...5 20 This page is intentionally left blank...
Page 328: ...B 6 This page is intentionally left blank...
Page 342: ...D 10 This page is intentionally left blank...
Page 354: ...E 12 This page is left intentionally blank...
Page 359: ......
Page 360: ......