INKA, IOR, REPO & LINK
3.5 Power Mode
For longer battery life, INKA and IOR can be configured to go into
power save mode
when the AC/DC
adapter is not connected, and when mains power is lost.
Power save mode is only intended for supervision of wired inputs 1-3. Inputs 4 and 5 are not available
for use, and no radio messages can be received in power save mode.
Please note that no battery alarms or radio test alarms are sent in power save mode.
When running on mains power with the AC/DC adapter connected, INKA and IOR are always in
normal power mode with all functionality enabled. REPO and LINK are always in normal power mode.
The
power mode
parameter is found in the
miscellaneous
section under the
preferences
tab in IOR
Programmer.
INKA
IOR
Enable
power save mode
Select “Yes/Function in” in list box 301
INKA
IOR
Disable
power save mode
Select “No/Function off” in list box 301
See section 2.2.8 for jumper configuration of the power mode.
3.6 Battery Charge Duration
IOR, REPO and LINK are equipped with a rechargeable battery for power back-up in case of AC
power failure. When one minute has passed after the power to the unit is turned on, the unit starts to
charge the back-up battery. The duration of the charging is configurable.
The
battery charge duration
parameter is found in the
miscellaneous
section under the
preferences
tab in IOR Programmer.
IOR
REPO
LINK
Configure the battery charge duration
Enter the desired time (in hours) in text
box 306
Technical Handbook for the IOR Family (firmware v20.x), document number NE41 06007-02 v1.0