Page 1: ...1 SUNCONTROL2 User manual ENGLISH VALID FOR THE FOLLOWING MODELS SCE 320 SCE 360 ...
Page 2: ...he European Directive 2012 19 EU Comply with local waste disposal regulations do not dispose of old products with normal household waste The proper disposal of products that can no longer be used prevents potential negative consequences for the environment and for the population ...
Page 3: ... 3 DESCRIPTION 3 4 OPERATIONS 5 5 STRUCTURE 6 6 N BUS NETWORK AND CONTROLLERS 7 7 INSTALLATION 8 8 CHARGING CURVE SELECTION 10 9 LED INDICATORS 13 10 FUSE REPLACEMENT 14 11 TECHNICAL FEATURES 15 12 WIRING DIAGRAMS SAMPLES 17 13 F A Q 20 14 WARRANTY 23 ...
Page 4: ...n very humid environments in contact with water splashes various liquids or exposed to rain To avoid risk of electric shock and or fire the vehicle s fuel system must be in good condition In case of damaged connecting cables or inadequate section immediately replace them with suitable cables as specified by this manual or by a qualified electrician In case of anomalies in the conformity of the pro...
Page 5: ...les to the maximum more energy less space The MPPT algorithm always uses the maximum power peak delivered by the panel with a significantly higher performance than the PWM technology up to 25 more SUNCONTROL2 available in two models SCE 320 and SCE 360 manages depending on the model up to 350W input with a maximum charge of 25A The new microprocessor equipped with OPTICHARGE firmware performs up t...
Page 6: ...r connections allows you to select the output charge curve in a simple and fast way The touch screen display DT002 optional with new management software allows you to view the charge information and set the various settings with the new communication protocol NDS MAIN FEATURES MPPT technology 25 performances Charging curve selection GEL AGM Wet and LiFePO4 New Firmware OPTICHARGE Up to 6 charging ...
Page 7: ...will be charged with the selected curve The Starting Battery will be charged if the following conditions are satisfied Leisure battery charged between 80 and 100 Starting battery with voltage under 12 5V Every charging phase have a maximum run time with the exception of the maintenance phase which constantly monitors the state of charge and if necessary delivers an impulse current to keep the batt...
Page 8: ... Solar panel negative connection 4 Battery negative connection 5 Solar panel positive connection 1 6 Solar panel positive connection 2 7 Leisure battery positive connection B1 8 Starter battery positive connection B2 9 Dip Switch Charging curve selection 10 Temperature probe connection 1 2 3 4 5 6 7 8 9 10 Fig 2 ...
Page 9: ...n full color display DTB01 or with the mobile app for smartphones if there is at least one NDS device with Bluetooth in the network Bluetooth devices are e g SUNCONTROL2 models with Bluetooth and TEMPRA Lithium Battery all models The mobile app can also be used to update all connected N BUS devices if there is a Master device such as TEMPRA Lithium Battery 7 DISPLAY MOBILE APP Bs 14 2 V ON 80 A 12...
Page 10: ...ide after the power connections there s a Dip Switch for the charging curve selection it s important to select the correct curve according to the type of battery supplied for the selection of the correct curve please refer to the chapter Charging curve selection 8 Fig 1 CAUTION For electrical connections use cables of appropriate cross section from 6 mm2 In case of a long stay it is advisable to d...
Page 11: ...BASIC CONNECTION 9 STARTER BATTERY SOLAR PANELS LEISURE BATTERY N BUS CHAIN ...
Page 12: ...3 OFF GEL Desulphation OFF Vmax 14 2V Vmaint 13 5V 2 1 ON 2 OFF 3 OFF Acido Libero Desulphation OFF Vmax 14 4V Vmaint 13 8V 3 1 OFF 2 ON 3 OFF AGM Desulphation OFF Vmax 14 7V Vmaint 13 6V 4 1 ON 2 ON 3 OFF AGM Desulphation ON Vmax 14 7V Vmaint 13 6V Vdes 15 8V 5 1 OFF 2 OFF 3 ON LiFePO4 Litio Maintenance ON Vmax 14 5V Vmaint 13 8V 6 1 ON 2 OFF 3 ON LiFePO4 Litio Maintenance OFF Vmax 14 5V 7 1 OFF ...
Page 13: ...oximately 2A costant current will be delivered Timeout 8 hours BULK CHARGE With voltage between 12V and Vmax Maximum voltage of the selected charging curve will be delivered a constant current of 20A model SCE 320 and 25A model SCE 360 NOTE The default setting is Curve 1 for GEL batteries desulphation OFF In order to safeguard the battery with an ambient temperature below 0 C the LiFePO4 charge cu...
Page 14: ...7 while for the other curves there s no time limit If during the maintenance phase the voltage should fall below 13 15V for LiFePO4 curve and 12 65V Wet curve and 12 8V and for the other curves charge will be restarted from the first phase Timeout 4 hours B2 PHASE DISCUSSION PULSE CHARGE With voltage between 8V and 10 5V a variable current between 1A and 2A every 5 seconds Timeout 4 hours RECONDIT...
Page 15: ...erred to a precise state of charge of the battery the table below explains the relationship between the LED color and the battery state of charge 13 SIGNAL MEANING Red LED Charging Orange LED Reconditioning Green LED Fully charged Maintenance CAUTION A fast flashing of both LEDs with the solar panel active shows an error due to the internal fuse breaking or services battery voltage below 6V ...
Page 16: ...plied or with a common 25A for SCE320 or 30A for SCE360 automotive fuse Follow these steps to reach the fuse 1 Remove SUNCONTROL2 from its housing 2 Rotate the device to reveal the screws on the bottom of the device 3 Unscrew the 4 screws 4 Remove the front shell of SUNCONTROL2 to access the fuse 5 Replace the fuse 14 Z FUSE 25A SCE320 30A SCE360 ...
Page 17: ...00W OUTPUT B1 Battery nominal voltage 12V 12V Charging current maximum output 20A 25A Minumum battery capacity required Lead acid 60Ah 80Ah Minumum battery capacity required LiFePO4 40Ah 50Ah Mimumum battery voltage required 8V 8V Charging curve selector Curves number Yes 8 Yes 8 Temperature regulated fan speed No Yes Temperature regulated charging by temperature sensor for B1 battery optional Yes...
Page 18: ...Weight cables excluded 400g 420g Working temperature 20 C 50 C 20 C 50 C Ambient humidity 90 no condensation 90 no condensation Maximum altitude 3000m maximum nominal output up to 2000m 3000m maximum nominal output up to 2000m OUTPUT B2 Battery nominal voltage 12V 12V Chargingcurrentmaximumoutput 5A 5A Minumum battery capacity required Lead acid LiFePO4 15Ah 10Ah 15Ah 10Ah Minimum maximum voltage ...
Page 19: ...ion with solar panels bus display optional 17 sun control 2 solar panel alternator leisure battery leisure battery solar panel 2 5 mm2 Max 6mm2 8 7 5 6 4 10 mm2 10 mm2 10A 30A display BUS N BUS CHAIN temperature probe optional TS002 34 5 6 7 8 ...
Page 20: ...ter battery leisure battery solar panel 2 5 mm2 35mm2 35mm2 35mm2 35mm2 Max 6 mm 2 8 7 5 6 3 3 10 mm2 10 mm2 10A 125A 30A 100A display BUS temperature probe optional TS002 34 5 6 7 8 aC DC control unit FRIDGE 12V APPLIANCE E G LIGHT WATER PUMP D 1 mm 2 alternator d B2 B1 35 mm2 13 4 11 12 13 14 N BUS CHAIN ...
Page 21: ...l 2 solar panel starter battery Tempra lithium battery leisure battery solar panel 2 5 mm2 Max 6 mm 2 8 7 5 6 3 3 10 mm2 10 mm2 10A 30A display BUS 34 5 6 7 8 aC DC control unit FRIDGE 12V APPLIANCE E G LIGHT WATER PUMP D 1 mm 2 alternator d B2 35 mm2 4 13 2 11 12 13 14 N BUS CHAIN 35mm2 35mm2 125A 35mm2 100A B1 ...
Page 22: ... one bigger solar panel 200W for example on SUNCONTROL2 Pin N 5 but you must connect Pin N 5 and Pin N 6 For the connection bridge please use at least a 6 mm2 cross size cable Is it normal to have a battery voltage with solar regulator working over 15V It s normal when the device is in desulphation mode It is possible to turn OFF the desulphation selecting the proper charging curve look at the cha...
Page 23: ...6 1 2019 EN IEC 61000 6 2 2019 EN IEC 61000 6 3 2021 It also complies with Directive 2014 53 EU RED for wireless communications equipment demonstrated by compliance with the standard EN 300220 For models with BLE connectivity SCE320B and SCE360B the radio equipment directive RED 2014 53 UE applies to compliance with the following regulations EN62368 1 2020 A11 2020 ETSI EN 301489 1 V2 2 3 2019 11 ...
Page 24: ... vehicles is demonstrated in compliance with the directive ECE R10 compliance with the restriction on the use of hazardous substances is demonstrated by compliance with directive 2011 65 EU ROHS2 22 Cappelle sul Tavo 14 06 2022 Administrator and legal representative ...
Page 25: ...__________________________________________ stamp and signature of the seller model_____________________________________ SERIAL NUMBER_____________________________ Purchase date_____________________________ I CONSENT TO THE ACTIVITY DESCRIBED IN POINT 3 C OF THE INFORMATION NOTICE ON www ndsenergy it privacy policy NDS ENERGY S r l Via G Pascoli 96 98 65010 Cappelle sul Tavo PE Italy email customer...