8. If the product touches water or is dropped in water,

fully

 

dry

 

before

 

use,

 

especially

 

water

 

on

 

the

 

surface

 

of

 

the

sensor

 

should

 

be

 

clean

ed with a 

cotton

 

swab.

Ou

r

 

aim

 

is

 

to

 

avoid

 

causing

 

safety

 

accidents

 

and

affecting

 

measurement

 

accuracy.

Caution:

1.

 Please do not use this product 

with

 people who suffer

from otitis external, tympanitis and other ear diseases.

It 

is possible to worsen the affected area.

2.

 Please do not use this product after swimming

, bathing

or

 with 

wet ears.

 It is possible to have 

a lower measurement

.

3.

 Do not place waste battery to danger zone.

The battery may break.

4.

 When measuring the ear temperature, the

 

product must

be operated in the ear temperature mode.

Can r

esult in inaccurate measurement result.

Suggestions

 

1.

When 

discussing 

you

r temperature measurement

results with a

 doctor, please 

specify to

 the doctor 

mode

(Forehead or Ear) that you measured in

.

2.

 Please don't force impact, fall, trample 

or

 shake this

product.

3.

 Please do not disassemble, repair 

or

 modify this product.

4.

 Please do not allow liquid to enter the body

 of the

product.

5.

 

Store the product in a 

clea

n, 

dry place.

6.

 If you find any problems, please contact the sales

 team

,

you

 

can not repair the product by yourself.

7.

 Please do not use under the environment of

electromagnetic interference.

8.

Please deal with the waste and residue of this product

at the end of the service life according to local laws and
regulations.

Common sense about body temperature

The comparison of different measurement methods.

The measured values are different if we use different 
measurement methods. The WHO provides normal human 
body temperature reference values, please see below table 
about the specific temperature difference.

The changes in human body temperature

Human

s

 

are

 constant 

body 

temperature animals, the body 

temperature is basically constant, but it is not totally 
changeless, the human body temperature is constantly 
changing in a day, the details 

are 

as follows:

At night  
Lowest  

Body temperature is lowest because of sleep and 

decreasing activity.(below 

98.6ºF

 )

In the morning
Higher   

From warm

 

bed to the lower temperature room   

in the morning, the whole body's muscles get 
contractions and produce heat.

At noon 
Highest 

After lunch, 

the 

human body reaches the highest 

temperature and the body will adjust naturally.

Three or four o’clock in the afternoon

 

Lower    

Due to physical exertion, blood sugar decrease

s

.

In the evening     
Lowest  

Due to sun down, 

the 

room temperature goes 

down.

Product layout

Measurement methods                 

Anal temperature

Normal body temperature

97.8ºF

 

 

~

 

100.4ºF

Head cover 

for

 

forehead temperature

06

05

mem

Display screen

Measurement display  

MEM

 

button

Power

 

button

Battery cover

Probe

Oral temperature

Axillary temperature          

Cochlear temperature       

Oral temperature

95.9ºF ~ 99.5ºF

94.5ºF ~ 99 ºF

96.5ºF ~ 100.4ºF

95.9ºF ~  99.5ºF 

 

(

PG-IRT1603

 measured value) 

Summary of Contents for PG-IRT1603

Page 1: ...mometer Thanks for buying and using this product please read this manual carefully before use User manual The USB Lighter Company LLC Address 10940 Wilshire Blvd STE 2010 Los Angeles CA 90024 949 682 8817 Brand NCT Date 06 16 2020 Rev A 0 ...

Page 2: ...ease do not use this product for purposes other than body temperature measurement Do not use mobile phones close to this product Please do not use equipment that generates electromagnetic fields near the product Please do not disassemble or repair this device by yourself Please do not bend or stretch the device Please do not impact or drop this product Caution please refer to attached file Legend ...

Page 3: ...outh When the infrared sensor is damaged or dirty it may cause abnormal measurement results 3 If there is a temperature difference between the storage site and the measurement site please place it at room temperature measurement site for about 30 minutes before next measurement May result in incorrect measurement results 4 Please keep this product out of the reach of children Children can potentia...

Page 4: ...idue of this product at the end of the service life according to local laws and regulations Common sense about body temperature The comparison of different measurement methods The measured values are different if we use different measurement methods The WHO provides normal human body temperature reference values please see below table about the specific temperature difference The changes in human ...

Page 5: ...s low LCD shows sign and battery mark is always on which means you should replace the battery Warm prompts If storing the product for an extended period please remove the battery to assure longevity Battery fluids may harm the product and pollute our environment It is recommended to use alkaline batteries The way to handle a scrapped battery should match the requirements of local country governmen...

Page 6: ... Measurement result Note If you did not hear the beep sound this means that the temperature measurement has not yet been completed Please do not remove the thermometer probe from forehead at this time If you have disabled the sound indication it will have no sound indication 3 Object pattern measurement The installation of the head cover of forehead temperature has no influence to object pattern m...

Page 7: ...H When you operate this product the environment temperature cannot be greater than 104 F Er L This product has a lower operating temperature of 50 F When the ambient temperature exceeds this temperature point the LCD screen will display an error message Er L When you operate this product the environment temperature can not be lower than 50 F The measurement temperature is low The measurement posit...

Page 8: ...kV 4 kV 8 kV 15 KV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 30A m 50 60Hz Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Specifications of the product Product name Infrared Forehead Ear Thermometer Model number...

Page 9: ...odel PG IRT1603 Infrared Thermometer is used exceeds the applicable RF compliance level above the Model PG IRT1603 Infrared Thermometer should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the Model PG IRT1603 Infrared Thermometer d Over the frequency range 150 kHz to 80 MHz field strengths should ...

Page 10: ...ed Maximum output of transmitter W Separation distance according to frequency of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 7 GHz P V d 5 3 1 P E d 5 3 1 P E d 7 1 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated usin...

Reviews: