5.2
Hydraulic tank part diagram
Item
Description
Specification
Q’y
1
Hydraulic tank (35 litre) 400×400×220
1
2
Oil level gauge
LS-3
1
3
Cooler
AW-407-CA
1
4
Pump
VPE-20-F-D
1
5
Motor
1HP-4P-220/380
1
6
Lubricator
HS-1162
1
7
Valve
CV-03
1
8
Board
1/4"
1
9
Pressure scale
100-KG
1
10
Oil filter net
MF-06
1
11
Manifold board
1w+2P+2T
1
12
Solenoid valve
DSGL-01-2D2-D24-N1 1
13
Solenoid valve
DSGL-01-3C2-D24-N1 1
14
Pressure reduce valve
MBR-02-P-1-K-50
2
15
Pressure scale
70-KG
2
16
Manifold board
02x2w
1
5.3
System pressure adjustment
The max. output pressure is 28 kgf/cm
2
, we can adjust and setting from the pressure valve on
the pump. During adjustment, you can confirm the value from the pressure scale. (The total
pressure setting is 28 kgf/cm
2
before shipping. )
Note:
Please don’t adjust pressure source to avoid any issue.