13
Document Number
DCV-00545
Date Released
Jul. 2020
Revision Number/Security level
R01 S2
Retrofit OPTIC 5 Touch+ InvencoLink Wayne Ovation (US & Canada)
Installation Guide
4 Installation Guide
1. Please ensure all safety procedures are followed per requirement by the customer before
installing the retrofit kit.
2. Remove power to Pump and follow the OSHA Lock-out/Tag-out procedures.
3.
This installation will require various panel replacements. The panels will be removed from the
door and replaced with pre-built panels with the OPT modules pre-fitted.
4.1
Disassembly Procedure
Before installation of the equipment can take place, the existing electronic payment assembly must be
removed from the dispenser. This section covers the removal of these components including:
•
QVGA Panel Assembly (with QCAT Board and QVGA Display)
•
Card Reader Assembly
•
Printer Assembly
•
Various Cable Assemblies
Note
: Throughout this disassembly procedure there are many cable assemblies that will be unplugged
and will not be reused. It is up to the discretion of the installer whether to remove these cables or position
them inside of the dispenser cavity. The loose cables need to be bundled and restrained using zip-ties or
cable restraints. After the cables have been bundled they must be placed in a location that will not cause
obstruction, exposure, or hazard.
Note
: It may be necessary to disconnect cable assemblies on various boards during this disassembly
procedure in order to more easily access other components. Disconnect these cables as necessary. It is
recommended that the installer of this kit either re-connect these cables immediately afterwards or mark
each disconnected cable before it is unplugged to make it easier to identify when it comes time for re-
installation.
1.
At the main disconnect panel, disconnect all power to the dispenser and the pump servicing the
dispenser. Tag all disconnected breakers to prevent others from reconnecting power.
Failure to turn off the unit during installation of the kit may cause injury or bodily harm from electrical shock.
Ensure that all power to the unit is switched off before opening the door of the unit and during kit installation.
WARNING